Central and Peripheral Corneal Thickness in Full-Term Newborns by Ultrasonic Pachymetry

作者: L Remon , JA Cristobal , J Castillo , T Palomar , A Palomar

DOI:

关键词:

摘要: To establish a standard of normality, the authors studied central and peripheral (superior, inferior, nasal, temporal) corneal thickness 152 healthy, white race, full-term newborns (304 eyes) between 1 6 days old, using ultrasonic pachymetry. The mean (CCT) was 585 ± 52 nm (ranging from 446-706 nm). (PCT), significantly thicker than CCT (P = 0.0001), was: superior (SCT) 696 55 /zm, inferior (ICT) 744 62 nm, nasal (NCT) 742 58 |im, temporal (TCT) 748 nm. SCT thinner ICT, NCT, TCT 0.0001). Differences among were not statistically significant. 1-day-old group 611 this being those other age groups differences male female babies right left eyes This is first study on at limbus in four meridians live newborns. Invest Ophthalmol Vis Sci 33:3080-3083,1992 Corneal edema main clinical sign primary congenital glaucoma. could be easily measured by However, standards for normal newborn are well described. As far as we know, there only five articles literature about 2 " Until now, no one has published data (PCT) life purpose to normality corneas PCT points: (SCT), (ICT), (NCT), (TCT). These values used reference early diagnosis control

参考文章(10)
Shingo Fujita, Diurnal Variation in Human Corneal Thickness Japanese Journal of Ophthalmology. ,vol. 24, pp. 444- 456 ,(1980)
NIELS EHLERS, TORBEN SØRENSEN, THORKILD BRAMSEN, ERIK HOLK POULSEN, CENTRAL CORNEAL THICKNESS IN NEWBORNS AND CHILDREN Acta Ophthalmologica. ,vol. 54, pp. 285- 290 ,(2009) , 10.1111/J.1755-3768.1976.TB01257.X
Lilly M.S. Dubowitz, Victor Dubowitz, Cissie Goldberg, Clinical assessment of gestational age in the newborn infant The Journal of Pediatrics. ,vol. 77, pp. 1- 10 ,(1970) , 10.1016/S0022-3476(70)80038-5
W. Portellinha, R. Belfort, Central and peripheral corneal thickness in newborns Acta Ophthalmologica. ,vol. 69, pp. 247- 250 ,(2009) , 10.1111/J.1755-3768.1991.TB02719.X
T. Autzen, L. Bjørnstrøm, Central corneal thickness in full-term newborns Acta Ophthalmologica. ,vol. 67, pp. 719- 720 ,(2009) , 10.1111/J.1755-3768.1989.TB04409.X
Craig A Bolton, Wesley K Herman, Corneal Thickness Changes During Ultrasound Pachymetry for Radial Keratotomy Journal of Refractive Surgery. ,vol. 2, pp. 221- 222 ,(1986) , 10.3928/1081-597X-19860901-07
August L Reader, James J Salz, Differences among ultrasonic pachymeters in measuring corneal thickness Journal of Refractive Surgery. ,vol. 3, pp. 7- 9 ,(1987) , 10.3928/1081-597X-19870101-04
Cooper Hd, May Se, Donzis Pb, Insler Ms, Analysis of corneal thickness and corneal curvature in infants. The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc. ,vol. 13, pp. 182- 184 ,(1987)
Ma Sf, [Ultrasonic biometric measurement of the corneal thickness of 1,008 newborn infants]. Chinese journal of ophthalmology. ,vol. 23, pp. 221- ,(1987)