Seven-Year Experience and Follow-Up with St. Jude Medical® Prostheses

作者: L. C. D’Alessandro , A. Pucci , P. Mamone , R. Cini

DOI: 10.1007/978-1-4684-6900-4_31

关键词:

摘要: At the Division of Cardiac Surgery St. Camillo Hospital, 1411 patients were operated on for valve replacement with ST. JUDE MEDICAL® prostheses from November 1978 through June 30, 1986. Six hundred eighty had mitral (MVR), 468 aortic (A VR), 5 tricuspid (TVR), 246 MVR + AVR, 8 TVR, 1 AVR 3 and as well ascending aorta a MEDICAL valved graft. The total number implanted was 1672. Associated procedures were: left atrium thrombectomy 98, repair 92, coronary artery bypass grafting 52, subaortic membrane 19, atrial septal defect closure 16. operative mortality rate 9.3% MVR, 5.8% 40% 6.8% 14% 66.6% 0% TVR. 7-year actuarial survival 78% 86% 80% AVR. 7 years, freedom thromboembolism 82% complete series, major events (prosthesis failure prosthesis thrombosis) 92%. Seven-year in concomitant similar to that without disease. Clinical improvement observed 97% patients.

参考文章(8)
Dale C. Wortham, Terry B. Tri, Thomas E. Bowen, Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus The Journal of Thoracic and Cardiovascular Surgery. ,vol. 81, pp. 615- 620 ,(1981) , 10.1016/S0022-5223(19)39496-6
Eugene M. Baudet, Catherine C. Oca, Xavier F. Roques, Marie N. Laborde, Abdullah S. Hafez, Monique A. Collot, Italo M. Ghidoni, A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients. The Journal of Thoracic and Cardiovascular Surgery. ,vol. 90, pp. 137- 144 ,(1985) , 10.1016/S0022-5223(19)38673-8
Cooley Da, Ott Da, Duncan Jm, Walker We, Livesay Jj, Reul Gj, Frazier Oh, The St. Jude medical valve: early clinical results in 253 patients. Texas Heart Institute Journal. ,vol. 10, pp. 11- 16 ,(1983)
Gary L. Grunkemeier, Albert Starr, Actuarial Analysis of Surgical Results: Rationale and Method The Annals of Thoracic Surgery. ,vol. 24, pp. 404- 408 ,(1977) , 10.1016/S0003-4975(10)63431-5
E. L. Kaplan, Paul Meier, Nonparametric Estimation from Incomplete Observations Springer Series in Statistics. ,vol. 53, pp. 319- 337 ,(1992) , 10.1007/978-1-4612-4380-9_25
J. Michael Duncan, Denton A. Cooley, George J. Reul, David A. Ott, Grady L. Hallman, O. Howard Frazier, James J. Livesay, William E. Walker, Phillip R. Adams, Durability and Low Thrombogenicity of the St. Jude Medical Valve at 5-Year Follow-up The Annals of Thoracic Surgery. ,vol. 42, pp. 500- 505 ,(1986) , 10.1016/S0003-4975(10)60571-1
R W Emery, E Mettler, D M Nicoloff, A new cardiac prosthesis: the St. Jude Medical cardiac valve: in vivo results. Circulation. ,vol. 60, pp. 48- 54 ,(1979) , 10.1161/01.CIR.60.2.48
Soji Konno, Yasuharu Imai, Yoshinao Iida, Masamichi Nakajima, Katuhiko Tatsuno, A new method for prosthetic valve replacement in congenital aortic stenosis associated with hypoplasia of the aortic valve ring. The Journal of Thoracic and Cardiovascular Surgery. ,vol. 70, pp. 909- 917 ,(1975) , 10.1016/S0022-5223(19)39673-4