作者: S. L. Mikerin , V. D. Ugozhaev
DOI: 10.1134/S0030400X11130133
关键词:
摘要: Results of analysis a very simple, compact interferometer for recording holographic diffraction gratings, which allows continuous tuning the angle between interfering beams from 0° to 80°, are presented. The device consists single optical element, beamsplitter cube. lengths arms in such an automatically equal, and is accomplished by changing incidence beam on input face. Formulas calculating principal characteristics derived. It shown that using cube material with higher index refraction increasing diameter broadening range. Recommendations design provided.