Dual-illumination mode, wide-field probe imaging scheme for imaging irido-corneal angle region inside eye

作者: Shinoj V. K. , Murukeshan V. M. , Jesmond Hong , M. Baskaran , Tin Aung

DOI: 10.1117/12.2189509

关键词:

摘要: Noninvasive medical imaging techniques have generated great interest and high potential in the research development of ocular follow up procedures. It is well known that angle closure glaucoma one major diseases/ conditions causes blindness. The identification treatment this disease are related primarily to assessment techniques. In paper, we illustrate a probe-based approach obtain images region eye. proposed probe consists micro CCD camera LED/NIR laser light sources they configured at distal end enable iridocorneal inside With dualmodal probe, performed (white visible LED ON) dark (NIR source alone) noticeable both cases. using NIR significance anterior chamber since it evades pupil constriction due bright thereby artificial altering angle. methodology developed scheme expected find application detection diagnosis.

参考文章(13)
Parikshit Gogate, Roma Deshpande, Vidya Chelerkar, Swapna Deshpande, Madan Deshpande, Is glaucoma blindness a disease of deprivation and ignorance? A case-control study for late presentation of glaucoma in India. Indian Journal of Ophthalmology. ,vol. 59, pp. 29- 35 ,(2011) , 10.4103/0301-4738.73720
Winifred P. Nolan, Jovina L. See, Paul T.K. Chew, David S. Friedman, Scott D. Smith, Sunita Radhakrishnan, Ce Zheng, Paul J. Foster, Tin Aung, Detection of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography in Asian Eyes Ophthalmology. ,vol. 114, pp. 33- 39 ,(2007) , 10.1016/J.OPHTHA.2006.05.073
H A Quigley, Number of people with glaucoma worldwide. British Journal of Ophthalmology. ,vol. 80, pp. 389- 393 ,(1996) , 10.1136/BJO.80.5.389
Shamira A. Perera, Mani Baskaran, David S. Friedman, Tin A. Tun, Hla M. Htoon, Rajesh S. Kumar, Tin Aung, Use of eyecam for imaging the anterior chamber angle Investigative Ophthalmology & Visual Science. ,vol. 51, pp. 2993- 2997 ,(2010) , 10.1167/IOVS.09-4418
François C. Delori, Robert H. Webb, David H. Sliney, Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices Journal of the Optical Society of America A. ,vol. 24, pp. 1250- 1265 ,(2007) , 10.1364/JOSAA.24.001250
V. K. Shinoj, V. M. Murukeshan, S. B. Tor, N. H. Loh, S. W. Lye, Design, fabrication, and characterization of thermoplastic microlenses for fiber-optic probe imaging Applied Optics. ,vol. 53, pp. 1083- 1088 ,(2014) , 10.1364/AO.53.001083
Shinoj Kuttinarayanan Vengalathunadakal, Vadakke M Murukeshan, Saraswathi Padmanabhan, Parasuraman Padmanabhan, None, Photonic crystal fiber–based dual-modality probe for simultaneous sensing and imaging applications Optical Engineering. ,vol. 48, pp. 103601- ,(2009) , 10.1117/1.3250294
L.K. Seah, U.S. Dinish, S.K. Ong, Z.X. Chao, V.M. Murukeshan, Time-resolved imaging of latent fingerprints with nanosecond resolution Optics and Laser Technology. ,vol. 36, pp. 371- 376 ,(2004) , 10.1016/J.OPTLASTEC.2003.10.006