作者: François C. Delori , Robert H. Webb , David H. Sliney
关键词:
摘要: After discussing the rationale and assumptions of the ANSI Z136. 1-2000 Standard for protection of the human eye from laser exposure, we present the concise formulation of the exposure limits expressed as maximum permissible radiant exposure (in J/cm^ 2) for light overfilling the pupil. We then translate the Standard to a form that is more practical for typical ophthalmic devices or in vision research situations, implementing the special qualifications of the Standard. The safety limits are then expressed as radiant power (watts) entering the …