Use of Polymer Inclusion Membranes (PIMs) as support for electromembrane extraction of non-steroidal anti-inflammatory drugs and highly polar acidic drugs

作者: Román-Hidalgo Cristina , Martín-Valero María Jesús , Fernández-Torres Rut , Bello-López Miguel Ángel

DOI: 10.1016/J.TALANTA.2017.11.066

关键词:

摘要: The use of polymer inclusion membranes (PIMs) as support 1-octanol liquid membrane in electromembrane extraction (EME) procedure is proposed. Synthesis PIMs were optimized to a composition 29% (w/w) cellulose triacetate base and 71% Aliquat®336 cationic carrier. Flat 25µm thickness 6mm diameter used. EME protocol was implemented for the simultaneous four non-steroidal anti-inflammatory drugs (NSAIDs) (salicylic acid, ketoprofen, naproxen ibuprofen) highly polar acidic (anthranilic nicotinic amoxicillin hippuric acid). Posterior HPLC separation extracted analytes developed with diode array detection. Recoveries 81-34% range obtained. applied human urine samples.

参考文章(32)
Nor Akma Mamat, Hong Heng See, Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane Journal of Chromatography A. ,vol. 1406, pp. 34- 39 ,(2015) , 10.1016/J.CHROMA.2015.06.020
Andrea Šlampová, Pavel Kubáň, Petr Boček, Quantitative aspects of electrolysis in electromembrane extractions of acidic and basic analytes Analytica Chimica Acta. ,vol. 887, pp. 92- 100 ,(2015) , 10.1016/J.ACA.2015.06.040
Elliot B Cham, JH Dykman, F Bochner, Urinary excretion of aspirin. British Journal of Clinical Pharmacology. ,vol. 14, pp. 562- 564 ,(1982) , 10.1111/J.1365-2125.1982.TB02030.X
Hong Heng See, Peter C. Hauser, Automated Electric-Field-Driven Membrane Extraction System Coupled to Liquid Chromatography–Mass Spectrometry Analytical Chemistry. ,vol. 86, pp. 8665- 8670 ,(2014) , 10.1021/AC5015589
María Ramos Payán, Miguel Ángel Bello López, Rut Fernández Torres, Mercedes Villar Navarro, Manuel Callejón Mochón, Electromembrane extraction (EME) and HPLC determination of non-steroidal anti-inflammatory drugs (NSAIDs) in wastewater samples Talanta. ,vol. 85, pp. 394- 399 ,(2011) , 10.1016/J.TALANTA.2011.03.076
Somsiri Decharat, Hippuric Acid Levels in Paint Workers at Steel Furniture Manufacturers in Thailand Safety and health at work. ,vol. 5, pp. 227- 233 ,(2014) , 10.1016/J.SHAW.2014.07.006
Hong Heng See, Simone Stratz, Peter C. Hauser, Electro-driven extraction across a polymer inclusion membrane in a flow-through cell. Journal of Chromatography A. ,vol. 1300, pp. 79- 84 ,(2013) , 10.1016/J.CHROMA.2013.01.062
T. Ishizaki, T. Sasaki, T. Suganuma, Y. Horai, K. Chiba, M. Watanabe, W. Asuke, H. Hoshi, Pharmacokinetics of ketoprofen following single oral, intramuscular and rectal doses and after repeated oral administration European Journal of Clinical Pharmacology. ,vol. 18, pp. 407- 414 ,(1980) , 10.1007/BF00636794