Identification of ten corticosteroids in human hair by liquid chromatography-ionspray mass spectrometry.

作者: V. Cirimele , P. Kintz , V. Dumestre , J.P. Goullé , B. Ludes

DOI: 10.1016/S0379-0738(99)00180-2

关键词:

摘要: This paper describes a screening procedure based upon high-performance liquid chromatography-ionspray mass spectrometry for the identification of ten corticosteroids in human hair: triamcinolone, prednisolone, prednisone, methylprednisolone, cortisone, cortisol, beta- and dexamethasone, flumethasone beclomethasone. Hair strands were washed methylene chloride, pulverized ball mill 50 mg powdered hair incubated 1 ml Soerensen buffer, pH 7.6 16 h at 40 degrees C, presence ng cortisol-d3 used as internal standard. Purification incubation medium was achieved on SPE C18 Isolute extraction columns. The eluates evaporated to dryness resuspended 30 microliters MeOH before analysis by HPLC-IS-MS positive negative modes detection. validation parameters found satisfactory corticosteroid procedure. correlation coefficient calibration curve ranged from 0.939 0.997, showing linearity between 0.1 10 ng/mg, excepted beclomethasone which 0.2 ng/mg. Extraction recovery 4 ng/mg 43.2 85.7%. Repeatability (CV values) 6.1 17.5%. limits detection 0.03 0.17 signal-to-noise ratio 2. prednisone three specimens obtained forensic clinical cases have documented incorporation into hair.

参考文章(8)
Pascal Kintz, Drug testing in hair Humana Press. pp. 67- 81 ,(2008) , 10.1007/978-1-59745-318-9_4
Hiromi Shibasaki, Takashi Furuta, Yasuji Kasuya, Quantification of corticosteroids in human plasma by liquid chromatography-thermospray mass spectrometry using stable isotope dilution Journal of Chromatography B: Biomedical Sciences and Applications. ,vol. 692, pp. 7- 14 ,(1997) , 10.1016/S0378-4347(96)00489-6
V. Cirimele, A. Tracqui, P. Kintz, B. Ludes, First identification of prednisone in human hair by liquid chromatography-ionspray mass spectrometry. Journal of Analytical Toxicology. ,vol. 23, pp. 225- 226 ,(1999) , 10.1093/JAT/23.3.225
Pascal Kintz, Hair testing and doping control in sport. Toxicology Letters. ,vol. 102, pp. 109- 113 ,(1998) , 10.1016/S0378-4274(98)00294-X
Logunov Vp, Mazkhar Sa, Chromatographic measurement of urinary steroids in patients with psoriasis Klinicheskaia laboratornaia diagnostika. pp. 11- ,(1994)
C. Hölzel, G. Spiteller, N. Buhles, L. Stöhr, H. Holzmann, P. Altmeyer, Influence of topical corticosteroids on hormones in urine and plasma. Drug Research. ,vol. 36, pp. 993- 996 ,(1986)
William J. Jusko, Nancy A. Pyszczynski, Mary S. Bushway, Robin D'Ambrosio, Suzette M. Mis, Fifteen years of operation of a high-performance liquid chromatographic assay for prednisolone, cortisol and prednisone in plasma Journal of Chromatography B: Biomedical Sciences and Applications. ,vol. 658, pp. 47- 54 ,(1994) , 10.1016/0378-4347(94)00218-5
Ph. Delahaut, P. Jacquemin, Y. Colemonts, M. Dubois, J. De Graeve, H. Deluyker, Quantitative determination of several synthetic corticosteriods by gas chromatography-mass spectrometry after purification by immunoaffinity chromatography Journal of Chromatography B: Biomedical Sciences and Applications. ,vol. 696, pp. 203- 215 ,(1997) , 10.1016/S0378-4347(97)00222-3