A Parametric Optimization of a Single Stage Regenerator Using REGEN 3.2

作者: J. M. Pfotenhauer , J. L. Shi , G. F. Nellis

DOI: 10.1007/0-387-27533-9_59

关键词:

摘要: Regenerative heat exchangers define the crucial design component for high frequency cryocoolers such as Stirling and Pulse Tube refrigerators. To aid in their design, a parametric investigation has been carried out using NIST code REGEN3.2 to optimize single-stage regenerator operating with warm end temperature of 300 K cold that varies between 60 80 K. The matrix choice all calculations is 400-mesh stainless steel. optimization defined by maximizing COP function geometry, mass flow, phase cold-end flow pressure. We have conducted over range 30 — Hz constant average pressure 20 bar ratio 1.2. Regenerator performance—defined net cooling power, losses—is presented along optimized parameters flux, angle order provide convenient charts regenerators.

参考文章(2)
R. Radebaugh, B. Louie, A simple, first step to the optimization of regenerator geometry National Bureau of Standards, Special Publication. ,vol. 698, pp. 177- 198 ,(1985)
D. E. Daney, R. Radebaugh, J. Gary, A computational model for a regenerator National Bureau of Standards, Special Publication. ,vol. 698, pp. 199- 211 ,(1985)