Zygomatic bone: anatomic bases for osseointegrated implant anchorage.

作者: Carlos Eduardo Francischone , Per-Ingvar Brånemark , José Angelo Camilli , Carlos Roberto Padovani , Maurício Bruhns Rigolizzo

DOI:

关键词:

摘要: Purpose The aim of the present study was to evaluate zygomatic bone thickness considering a possible relationship between this parameter and cephalic index (CI) for better use CI in implant placement technique. Materials methods calculated 60 dry Brazilian skulls. bones skulls were divided into 13 standardized sections measurement. Bilateral measurements made on Results Sections 5, 6, 8, 9 appropriate anchorage terms location. mean thicknesses these 6.05 mm section 3.15 6.13 4.75 9. In only 1 section, did side skull differ significantly from other (P Discussion For quadrant CI, 6 8 varied independently CI. Section 5 associated with brachycephaly, subbrachycephaly, presented variations corresponding thickness. Conclusion Based results, implants should be placed since they greatest thickness, except brachycephalic subjects, where subbrachycephalic not prove an evaluating sampling. (More than 50 references.)

参考文章(40)
D L Moore, R M Wood, Grafting of the maxillary sinus with intraorally harvested autogenous bone prior to implant placement. International Journal of Oral & Maxillofacial Implants. ,vol. 3, pp. 209- 214 ,(1988)
S L Graves, The pterygoid plate implant: a solution for restoring the posterior maxilla. International Journal of Periodontics & Restorative Dentistry. ,vol. 14, pp. 512- 523 ,(1994)
Hernandez Re, Lee Hy, Balshi Tj, The use of pterygomaxillary implants in the partially edentulous patient: a preliminary report. International Journal of Oral & Maxillofacial Implants. ,vol. 10, pp. 89- 98 ,(1995)
K E Kahnberg, Elisabeth Nyström, L Bartholdsson, Combined use of bone grafts and Brånemark fixtures in the treatment of severely resorbed maxillae. International Journal of Oral & Maxillofacial Implants. ,vol. 4, pp. 297- 304 ,(1989)
John Paul Stella, Michael R. Warner, Sinus Slot Technique for Simplification and Improved Orientation of Zygomaticus Dental Implants: A Technical Note International Journal of Oral & Maxillofacial Implants. ,vol. 15, pp. 889- 893 ,(2000)
Tjellström A, Jacobsson M, Granström G, Titanium implants in irradiated tissue: benefits from hyperbaric oxygen. International Journal of Oral & Maxillofacial Implants. ,vol. 7, pp. 15- 25 ,(1992)
Per-Ingvar Brånemark, Marcelo Ferraz de Oliveira, Kenji Higuchi, Rehabilitation of complex cleft palate and craniomaxillofacial defects : the challenge of Bauru Quintessence Pub. Co.. ,(1999)
U. Lekholm, Patient selection and preparation Tissue Integrated Prostheses : Osseointegration in Clinical Dentistry. pp. 199- 209 ,(1985)
Stefan Lundgren, Lars Rasmusson, Mats Sjostrom, Lars Sennerby, Simultaneous or delayed placement of titanium implants in free autogenous iliac bone grafts. Histological analysis of the bone graft-titanium interface in 10 consecutive patients. International Journal of Oral and Maxillofacial Surgery. ,vol. 28, pp. 31- 37 ,(1999) , 10.1034/J.1399-0020.1999.280108.X
C.-J. Ivanoff, L. Sennerby, U. Lekholm, Influence of mono- and bicortical anchorage on the integration of titanium implants International Journal of Oral and Maxillofacial Surgery. ,vol. 25, pp. 229- 235 ,(1996) , 10.1016/S0901-5027(96)80036-1