Hook Effect correction & resistance-based Cole fitting prior Cole model-based analysis: Experimental validation

作者: R Buendia , F Seoane , M Harris , J Caffarel , R Gil

DOI: 10.1109/IEMBS.2010.5627109

关键词:

摘要: The analysis of measurements Electrical Bioimpedance (EBI) is on the increase for performing non-invasive assessment health status and monitoring pathophysiological mechanisms. EBI might contain artefacts that must be carefully removed prior to any further analysis. Cole model-based often selected when analysing data lead miss-conclusion if it applied contaminated with measurement artefacts. recently proposed Correction Function eliminate influence Hook Effect from fitting real part model extract parameters have been validated experimental measurements. obtained results confirm feasible use these promising pre-processing tools improve outcome applications using

参考文章(10)
Jens Muehlsteff, Olaf Such, Richard Willmann, The Role of Technology for Non-Invasive Cardiovascular Monitoring in the Future Exemplified Springer Berlin Heidelberg. pp. 388- 391 ,(2009) , 10.1007/978-3-642-03885-3_108
H Scharfetter, P Hartinger, H Hinghofer-Szalkay, H Hutten, A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy Physiological Measurement. ,vol. 19, pp. 247- 261 ,(1998) , 10.1088/0967-3334/19/2/012
A. De Lorenzo, A. Andreoli, J. Matthie, P. Withers, Predicting body cell mass with bioimpedance by using theoretical methods: a technological review Journal of Applied Physiology. ,vol. 82, pp. 1542- 1558 ,(1997) , 10.1152/JAPPL.1997.82.5.1542
Milton Packer, William T Abraham, Mandeep R Mehra, Clyde W Yancy, Christine E Lawless, Judith E Mitchell, Frank W Smart, Rachel Bijou, Christopher M O’Connor, Barry M Massie, Ileana L Pina, Barry H Greenberg, James B Young, Daniel P Fishbein, Paul J Hauptman, Robert C Bourge, John E Strobeck, Srinvivas Murali, Douglas Schocken, John R Teerlink, Wayne C Levy, Robin J Trupp, Marc A Silver, Prospective Evaluation and Identification of Cardiac Decompensation by ICG Test (PREDICT) Study Investigators and Coordinators, None, Utility of Impedance Cardiography for the Identification of Short-Term Risk of Clinical Decompensation in Stable Patients With Chronic Heart Failure Journal of the American College of Cardiology. ,vol. 47, pp. 2245- 2252 ,(2006) , 10.1016/J.JACC.2005.12.071
Cheuk-Man Yu, Li Wang, Elaine Chau, Raymond Chan, Shun-Ling Kong, Robert W. Stadler, Chu-Pak Lau, Device-Based Intra-Thoracic Impedance Correlates with Fluid Status and Provides Automated Prediction of CHF Hospitalization Journal of Cardiac Failure. ,vol. 10, pp. S113- ,(2004) , 10.1016/J.CARDFAIL.2004.06.353
K. S. Cole, PERMEABILITY AND IMPERMEABILITY OF CELL MEMBRANES FOR IONS Cold Spring Harbor Symposia on Quantitative Biology. ,vol. 8, pp. 110- 122 ,(1940) , 10.1101/SQB.1940.008.01.013
Joerg Habetha, The myheart project - fighting cardiovascular diseases by prevention and early diagnosis international conference of the ieee engineering in medicine and biology society. pp. 6746- 6749 ,(2006) , 10.1109/IEMBS.2006.260937
R Buendia, F Seoane, R Gil-Pita, A novel approach for removing the hook effect artefact from Electrical Bioimpedance spectroscopy measurements international conference electrical bioimpedance. ,vol. 224, pp. 012126- ,(2010) , 10.1088/1742-6596/224/1/012126
D. Ayllon, F. Seoane, R. Gil-Pita, Cole equation and parameter estimation from electrical bioimpedance spectroscopy measurements - A comparative study international conference of the ieee engineering in medicine and biology society. ,vol. 2009, pp. 3779- 3782 ,(2009) , 10.1109/IEMBS.2009.5334494
Lisa Beckmann, Dirk van Riesen, Steffen Leonhardt, Optimal electrode placement and frequency range selection for the detection of lung water using Bioimpedance Spectroscopy international conference of the ieee engineering in medicine and biology society. ,vol. 2007, pp. 2685- 2688 ,(2007) , 10.1109/IEMBS.2007.4352882