Sources of error in intraocular lens power calculation.

作者: Thomas Olsen

DOI: 10.1016/S0886-3350(13)80917-0

关键词:

摘要: … , the IOL power was calculated using a "theoretical" formula like the Binkhorst formula10 and … formulas or according to mathematical models of the anterior segment in other formulas. …

参考文章(16)
M A Galin, A Linksz, S N Fyodorov, Calculation of the optical power of intraocular lenses Investigative Ophthalmology & Visual Science. ,vol. 14, pp. 625- 628 ,(1975)
Richard D Binkhorst, The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surgery and Lasers. ,vol. 12, pp. 363- 365 ,(1981) , 10.3928/1542-8877-19810501-16
Hans Freudiger, Lorenzo Artaria, Peter Niesel, Influence of intraocular lenses on ultrasound axial length measurement: in vitro and in vivo studies. American Intra-Ocular Implant Society Journal. ,vol. 10, pp. 29- 34 ,(1984) , 10.1016/S0146-2776(84)80073-7
Thomas Olsen, Prediction of intraocular lens position after cataract extraction Journal of Cataract & Refractive Surgery. ,vol. 12, pp. 376- 379 ,(1986) , 10.1016/S0886-3350(86)80099-2
Jack T. Holladay, Kathryn H. Musgrove, Thomas C. Prager, John W. Lewis, Thomas Y. Chandler, Richard S. Ruiz, A three-part system for refining intraocular lens power calculations Journal of Cataract and Refractive Surgery. ,vol. 14, pp. 17- 24 ,(1988) , 10.1016/S0886-3350(88)80059-2
Kenneth J. Hoffer, Biometry of 7,500 Cataractous Eyes American Journal of Ophthalmology. ,vol. 90, pp. 360- 368 ,(1980) , 10.1016/S0002-9394(14)74917-7
Randall J. Olson, Harry Kolodner, Herbert E. Kaufman, The Optical Quality of Currently Manufactured Intraocular Lenses American Journal of Ophthalmology. ,vol. 88, pp. 548- 555 ,(1979) , 10.1016/0002-9394(79)90513-0
Thomas Olsen, Theoretical approach to intraocular lens calculation using Gaussian optics. Journal of Cataract and Refractive Surgery. ,vol. 13, pp. 141- 145 ,(1987) , 10.1016/S0886-3350(87)80128-1
Thomas Olsen, Calculating axial length in the aphakic and the pseudophakic eye Journal of Cataract and Refractive Surgery. ,vol. 14, pp. 413- 416 ,(1988) , 10.1016/S0886-3350(88)80150-0