Electrochemical parameters of ethamsylate at multi-walled carbon nanotube modified glassy carbon electrodes

作者: Sheng-Fu Wang , Qiao Xu

DOI: 10.1016/J.BIOELECHEM.2005.12.005

关键词:

摘要: Abstract In this paper, some electrochemical parameters of ethamsylate at a multi-walled carbon nanotube modified glassy electrode, such as the charge number, exchange current density, standard heterogeneous rate constant and diffusion coefficient, were measured by cyclic voltammetry, chronoamperometry chronocoulometry. The electrode exhibits good promotion reaction increases greatly. differential pulse voltammetry responses linearly dependent on its concentrations in range from 2.0 × 10 − 6 to 6.0 × 10 − 5 mol L − 1 , with detection limit 4.0 × 10 − 7 .

参考文章(20)
Teri Wang Odom, Jin-Lin Huang, Philip Kim, Charles M Lieber, None, Atomic structure and electronic properties of single-walled carbon nanotubes Nature. ,vol. 391, pp. 62- 64 ,(1998) , 10.1038/34145
Jason J. Davis, Richard J. Coles, H. Allen, O. Hill, Protein electrochemistry at carbon nanotube electrodes Journal of Electroanalytical Chemistry. ,vol. 440, pp. 279- 282 ,(1997) , 10.1016/S0022-0728(97)80067-8
J.W. Jang, D.K. Lee, C.E. Lee, T.J. Lee, C.J. Lee, S.J. Noh, Metallic conductivity in bamboo-shaped multiwalled carbon nanotubes Solid State Communications. ,vol. 122, pp. 619- 622 ,(2002) , 10.1016/S0038-1098(02)00153-9
P. M. Ajayan, Nanotubes from Carbon. Chemical Reviews. ,vol. 99, pp. 1787- 1800 ,(1999) , 10.1021/CR970102G
Jia-Quan Chen, Jun-Feng Song, Liang-Feng Chen, Determination of ethamsylate in pharmaceutical preparations by irreversible biamperometry Microchemical Journal. ,vol. 80, pp. 65- 70 ,(2005) , 10.1016/J.MICROC.2004.11.002
Sumio Iijima, Helical microtubules of graphitic carbon Nature. ,vol. 354, pp. 56- 58 ,(1991) , 10.1038/354056A0
Joseph Wang, Mustafa Musameh, Yuehe Lin, Solubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors Journal of the American Chemical Society. ,vol. 125, pp. 2408- 2409 ,(2003) , 10.1021/JA028951V
Joseph Wang, Mustafa Musameh, Carbon nanotube/teflon composite electrochemical sensors and biosensors. Analytical Chemistry. ,vol. 75, pp. 2075- 2079 ,(2003) , 10.1021/AC030007+
Fengzhen Yang, Chao Zhang, Willy R.G Baeyens, Xinrong Zhang, Determination of ethamsylate in pharmaceutical preparations based on an auto-oxidation chemiluminescence reaction Journal of Pharmaceutical and Biomedical Analysis. ,vol. 30, pp. 473- 478 ,(2002) , 10.1016/S0731-7085(02)00096-1