作者: Juan Lopez-Garcia , Tony Sample
DOI: 10.1016/J.SOLENER.2017.12.018
关键词:
摘要: Abstract This work outlines the evolution of measured module parameters (power Pmax, short circuit current Isc, open voltage Voc) vs labelled crystalline silicon PV modules over a number decades at European Solar Test Installation (ESTI) Ispra, Italy. Manufacturers' tolerance in nameplate power has changed years with many claiming ±10% 80s and 90s. The declared recent been reduced to ±5% then ±3% today values −0/+3% are quite common. To know an operational system is useful additional information when investigating aging systems, original may either be unknown or missing passage decades. Therefore, researchers have often rely on for starting point system. Measurements ESTI laboratory performed since early 1980s. A comparison those which incorporated (or associated datasheet, flash report online information) their output (Pmax, Isc carried out. impact these differences from economic view also analysed. presents some selected results set 992 based modules, extracted various time periods 1982 2014.