Accumulated hard tissue debris produced during reciprocating and rotary nickel-titanium canal preparation.

作者: Gustavo De-Deus , Juliana Marins , Emmanuel João Nogueira Leal Silva , Erick Souza , Felipe Gonçalves Belladonna

DOI: 10.1016/J.JOEN.2014.11.028

关键词:

摘要: Abstract Introduction This study compared the amount of hard tissue debris produced after different apical enlargement with single-file reciprocating systems (WaveOne [Dentsply Maillefer, Baillaigues, Switzerland] and Reciproc [VDW, Munich, Germany]) a conventional multifile rotary system (BioRaCe [FKG Dentaire, La-Chaux-de-Fonds, Switzerland]) using micro–computed tomographic imaging. Methods Thirty moderately curved mesial roots mandibular molars presenting 2 independent root canals were selected scanned at an isotropic resolution 14.16 μm. The sample was assigned to 3 groups (n = 10) respect length degree curvature according used for canal preparation: Reciproc, WaveOne, BioRaCe. Second third scans taken prepared up ISO sizes 25 40, respectively. matched images canals, before preparation, examined from furcation level apex evaluate (%). Data statistically general linear model repeated-measures significance set 5%. Results Instrumentation per se did not influence accumulation (P > .05), whereas significant reduction in percentage observed sequential all Conclusions None yielded completely free packed debris. increased final size resulted significantly less both systems.

参考文章(27)
F. Paqué, C. Boessler, M. Zehnder, Accumulated hard tissue debris levels in mesial roots of mandibular molars after sequential irrigation steps. International Endodontic Journal. ,vol. 44, pp. 148- 153 ,(2011) , 10.1111/J.1365-2591.2010.01823.X
Gustavo De-Deus, Juliana Marins, Aline de Almeida Neves, Claudia Reis, Sandra Fidel, Marco A. Versiani, Haimon Alves, Ricardo Tadeu Lopes, Sidnei Paciornik, Assessing Accumulated Hard-tissue Debris Using Micro–computed Tomography and Free Software for Image Processing and Analysis Journal of Endodontics. ,vol. 40, pp. 271- 276 ,(2014) , 10.1016/J.JOEN.2013.07.025
Frank Paqué, Andres Laib, Hanspeter Gautschi, Matthias Zehnder, Hard-Tissue Debris Accumulation Analysis by High-Resolution Computed Tomography Scans Journal of Endodontics. ,vol. 35, pp. 1044- 1047 ,(2009) , 10.1016/J.JOEN.2009.04.026
R. Gergi, N. Osta, G. Bourbouze, C. Zgheib, R. Arbab-Chirani, A. Naaman, Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography International Endodontic Journal. ,vol. 48, pp. 162- 170 ,(2015) , 10.1111/IEJ.12296
Sung-Yeop You, Hyeon-Cheol Kim, Kwang-Shik Bae, Seung-Ho Baek, Kee-Yeon Kum, WooCheol Lee, None, Shaping Ability of Reciprocating Motion in Curved Root Canals: A Comparative Study with Micro–Computed Tomography Journal of Endodontics. ,vol. 37, pp. 1296- 1300 ,(2011) , 10.1016/J.JOEN.2011.05.021
N USMAN, J BAUMGARTNER, J MARSHALL, Influence of instrument size on root canal debridement. Journal of Endodontics. ,vol. 30, pp. 110- 112 ,(2004) , 10.1097/00004770-200402000-00012
Jonathan P. Robinson, Philip J. Lumley, Ela Claridge, Paul R. Cooper, Liam M. Grover, Richard L. Williams, A. Damien Walmsley, An analytical Micro CT methodology for quantifying inorganic dentine debris following internal tooth preparation Journal of Dentistry. ,vol. 40, pp. 999- 1005 ,(2012) , 10.1016/J.JDENT.2012.08.007
P. Kiefner, M. Ban, G. De-Deus, Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments International Endodontic Journal. ,vol. 47, pp. 430- 436 ,(2014) , 10.1111/IEJ.12166
Marcus Vinícius de Melo Ribeiro, Yara Terezinha Silva-Sousa, Marco Aurélio Versiani, Alessandro Lamira, Liviu Steier, Jesus Djalma Pécora, Manoel Damião de Sousa-Neto, None, Comparison of the Cleaning Efficacy of Self-Adjusting File and Rotary Systems in the Apical Third of Oval-shaped Canals Journal of Endodontics. ,vol. 39, pp. 398- 401 ,(2013) , 10.1016/J.JOEN.2012.11.016