Particle Accelerator Design

作者: Reinaldo J. Perez

DOI: 10.1016/B978-012550711-0/50015-5

关键词:

摘要: The earliest radiation sources known to humans were provided by gas-filled x-ray tubes. A dramatic increase in the photon energy was made possible 1943 with development of a new accelerator as betatron. Betatrons deliver X rays such properties skin sparing, greater depth dose, and less side scatter than those generated X-ray tubes radioisotope sources. main disadvantage betatron is relatively low intensity beam well small treatment field area. limitation betatrons capability RF linear accelerators provide high dose rate have contributed rise their dominant role among world's radiotherapy machines. In radiobiological studies, charged particle advantages over other ionizing for medical cancer: considerably higher energies can be achieved, easily controlled accelerated constitute an additional parameter some experiments, variety mass numbers bombarding ions provides options, beams currents eliminate risks chemical contamination. Electrical acceleration particles basis accelerators. These range from electrons ions. Applications various biomedical applications corresponding typical ranges are provided.

参考文章(14)
P. G. Morris, P. Mansfield, Nmr Imaging in Biomedicine ,(1982)
Gregory A. Loew, Richard Talman, Elementary principles of linear accelerators Physics of High Energy Particle Accelerators-1982. ,vol. 105, pp. 1- 91 ,(1983) , 10.1063/1.34235
William R. Hendee, X Rays in Medicine Physics Today. ,vol. 48, pp. 51- 56 ,(1995) , 10.1063/1.881440
G.K.Y. Lam, G.B. Goodman, R.W. Harrison, L.D. Skarsgard, R.O. Kornelsen, Cancer radiotherapy using negative pi-mesons☆ Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms. ,vol. 10, pp. 1096- 1101 ,(1985) , 10.1016/0168-583X(85)90179-X
Craig S. Nunan, Design and performance criteria for medical electron accelerators Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms. ,vol. 10, pp. 881- 887 ,(1985) , 10.1016/0168-583X(85)90130-2
D. K. Bewley, The 8 MeV linear accelerator at the MRC Cyclotron Unit, Hammersmith Hospital, London. British Journal of Radiology. ,vol. 58, pp. 213- 217 ,(1985) , 10.1259/0007-1285-58-687-213
Robert G. Griffin, C. P. Slichter, Principles of magnetic resonance ,(1963)
Felix W. Wehrli, The Origins and Future of Nuclear Magnetic Resonance Imaging Physics Today. ,vol. 45, pp. 34- 42 ,(1992) , 10.1063/1.881310
James M. Slater, Daniel W. Miller, John O. Archambeau, Development of a hospital-based proton beam treatment center International Journal of Radiation Oncology Biology Physics. ,vol. 14, pp. 761- 775 ,(1988) , 10.1016/0360-3016(88)90099-5