Surfactant/oil/water system for the determination of selenium in eggs by graphite furnace atomic absorption spectrometry

作者: C.V.S. Ieggli , D. Bohrer , S. Noremberg , P.C. do Nascimento , L.M. de Carvalho

DOI: 10.1016/J.SAB.2009.05.007

关键词:

摘要: Abstract An oil-in-water formulation has been optimized to determine trace levels of selenium in whole hen eggs by graphite furnace atomic absorption spectrometry. This method is simpler and requires fewer reagents when compared with other sample pre-treatment procedures. Graphite spectrometric (GF AAS) measurement was carried out using standard addition calibration Pd as a modifier. The precision, expressed relative deviation, better than 5% the limit detection 1 µg L − 1 . validation performed against reference material Whole Egg Powder (RM 8415), measured Se corresponded 95.2% certified value. used for determination level from hens treated dietary supplements. Inorganic organic sources were added feed. content higher fed treatments. proposed method, including emulsification subsequent GF AAS proved be sensitive, reproducible, simple economical.

参考文章(16)
A. Sanz-Medel, M.R.Fernandez de la Campa, M.C.Valdes-Hevia y Temprano, B.Aizpun Fernandez, Y.M. Liu, Surfactant-based ordered media in analytical atomic spectrometry☆ Talanta. ,vol. 40, pp. 1759- 1768 ,(1993) , 10.1016/0039-9140(93)80094-8
V Kiosseoglou, Egg yolk protein gels and emulsions Current Opinion in Colloid and Interface Science. ,vol. 8, pp. 365- 370 ,(2003) , 10.1016/S1359-0294(03)00094-3
Ignác Capek, Degradation of kinetically-stable o/w emulsions. Advances in Colloid and Interface Science. ,vol. 107, pp. 125- 155 ,(2004) , 10.1016/S0001-8686(03)00115-5
Cuiling Pan, Kehe Huang, Yuxin Zhao, Shunyi Qin, Fu Chen, Qiuhui Hu, Effect of Selenium Source and Level in Hen's Diet on Tissue Selenium Deposition and Egg Selenium Concentrations Journal of Agricultural and Food Chemistry. ,vol. 55, pp. 1027- 1032 ,(2007) , 10.1021/JF062010A
Denise Bohrer, Emilene Becker, Paulo Cícero do Nascimento, Morgana Dessuy, Leandro Machado de Carvalho, Comparison of graphite furnace and hydride generation atomic absorption spectrometry for the determination of selenium status in chicken meat Food Chemistry. ,vol. 104, pp. 868- 875 ,(2007) , 10.1016/J.FOODCHEM.2006.10.008
Annalisa Bargellini, Isabella Marchesi, Laura Rizzi, Laura Cauteruccio, Roberto Masironi, Marco Simioli, Paola Borella, Selenium interactions with essential and toxic elements in egg yolk from commercial and fortified eggs Journal of Trace Elements in Medicine and Biology. ,vol. 22, pp. 234- 241 ,(2008) , 10.1016/J.JTEMB.2008.03.004
Nadezda A. Golubkina, Tigran T. Papazyan, Selenium distribution in eggs of avian species Comparative Biochemistry and Physiology B. ,vol. 145, pp. 384- 388 ,(2006) , 10.1016/J.CBPB.2006.08.007