An impedimetric biosensor to test neat serum for dengue diagnosis

作者: JULIANA CECCHETTO , FERNANDA C. CARVALHO , ADRIANO SANTOS , FLÁVIO C.B. FERNANDES , PAULO R. BUENO

DOI: 10.1016/J.SNB.2015.02.068

关键词:

摘要: Abstract NS1, a non-structural dengue protein, has been used as biomarker for the detection of viremia in diagnosis. In this work, an impedimetric label-free immunosensor based on anti-NS1 modified gold electrode was developed. To immobilize anti-NS1, mixed self-assembled monolayer consisting 11-mercaptoundecanoic acid (for covalent attachment) and 6-mercaptohexanol (as spacer) prepared. The impedance spectra were recorded presence redox probe ([Fe(CN)6]3−/4−) to monitor changes charge-transfer resistance associated with target binding both PBS neat serum. A calibration curve constructed order obtain analytical parameters. NS1 diluted final concentrations linear range 0.01–2.00 μg mL−1 sensitivity 14.1 percentage decade−1 (R ∼ 0.99) limit (LOD) 3 ng mL−1. 0.01–1.00 μg mL−1 serum also obtained (R ∼ 0.98) 10.4 percentage decade−1 LOD 30 ng mL−1. results open new insights into potential use biosensor point-of-care bedside applications

参考文章(22)
R S Lanciotti, C H Calisher, D J Gubler, G J Chang, A V Vorndam, Rapid detection and typing of dengue viruses from clinical samples by using reverse transcriptase-polymerase chain reaction. Journal of Clinical Microbiology. ,vol. 30, pp. 545- 551 ,(1992) , 10.1128/JCM.30.3.545-551.1992
V. Kumarasamy, A.H. Abdul Wahab, S.K. Chua, Z. Hassan, Y.K. Chem, M. Mohamad, K.B. Chua, Evaluation of a commercial dengue NS1 antigen-capture ELISA for laboratory diagnosis of acute dengue virus infection Journal of Virological Methods. ,vol. 140, pp. 75- 79 ,(2007) , 10.1016/J.JVIROMET.2006.11.001
Chih-Cheng Su, Tzong-Zeng Wu, Li-Kuang Chen, Hui-Hua Yang, Dar-Fu Tai, Development of immunochips for the detection of dengue viral antigens Analytica Chimica Acta. ,vol. 479, pp. 117- 123 ,(2003) , 10.1016/S0003-2670(02)01529-5
Eili Huhtamo, Essi Hasu, Nathalie Y. Uzcátegui, Elina Erra, Simo Nikkari, Anu Kantele, Olli Vapalahti, Heli Piiparinen, Early diagnosis of dengue in travelers: Comparison of a novel real-time RT-PCR, NS1 antigen detection and serology Journal of Clinical Virology. ,vol. 47, pp. 49- 53 ,(2010) , 10.1016/J.JCV.2009.11.001
R W Peeling, K K Holmes, D Mabey, A Ronald, Rapid tests for sexually transmitted infections (STIs) : the way forward Sexually Transmitted Infections. ,vol. 82, ,(2006) , 10.1136/STI.2006.024265
Gary L. Long, J. D. Winefordner, Limit of detection. A closer look at the IUPAC definition Analytical Chemistry. ,vol. 55, ,(1983) , 10.1021/AC00258A001
FLÁVIO C.B. FERNANDES, ADRIANO SANTOS, DENISE C. MARTINS, MÁRCIO S. GÓES, PAULO R. BUENO, None, Comparing label free electrochemical impedimetric and capacitive biosensing architectures Biosensors and Bioelectronics. ,vol. 57, pp. 96- 102 ,(2014) , 10.1016/J.BIOS.2014.01.044
Thomas Bryan, Xiliang Luo, Paulo R. Bueno, Jason J. Davis, An optimised electrochemical biosensor for the label-free detection of C-reactive protein in blood. Biosensors and Bioelectronics. ,vol. 39, pp. 94- 98 ,(2013) , 10.1016/J.BIOS.2012.06.051
Anthony Johnson, Qifeng Song, Paul Ko Ferrigno, Paulo R. Bueno, Jason J. Davis, Sensitive affimer and antibody based impedimetric label-free assays for C-reactive protein. Analytical Chemistry. ,vol. 84, pp. 6553- 6560 ,(2012) , 10.1021/AC300835B