Performance Investigation of Solar Evacuated Tube Collector Using TRNSYS in Tehran

作者: Alibakhsh Kasaeian , Ahmadreza Mohammadkarim , Abdolrazagh Kaabinejadian

DOI:

关键词:

摘要: Outlet temperature of the collector for efficiency water-in-glass evacuated tube solar domestic hot water system with natural circulation is generally more than flat plate systems. Additionally, this type collectors free economically cheaper heat pipes systems, widely used in world. This paper dedicated to simulation heating under climatic conditions Tehran city TRNSYS software. Diagram components has fully been studied including Type71 horizontal tank above it and five nodes vertically stratified order control temperatures out collector. Vertical increases household uses. After we obtain regression linear curve against loss spring summer seasons irradiation mean ambient each selected day. Normal 0 false EN-US X-NONE AR-SA

参考文章(15)
Ishioma Ani Odigwe, Oluwakorede Olakunle Ologun, Oluwaseyi Olatokun, Awelewa Ajibola Ayokunle, Ayoade Felix Agbetuyi, Samuel Adekunle Isaac, None, A Microcontroller-Based Active Solar Water Heating System for Domestic Applications International Journal of Renewable Energy Research. ,vol. 3, pp. 837- 845 ,(2013) , 10.20508/IJRER.32688
Indra Budihardjo, Graham L. Morrison, Masud Behnia, Natural circulation flow through water-in-glass evacuated tube solar collectors Solar Energy. ,vol. 81, pp. 1460- 1472 ,(2007) , 10.1016/J.SOLENER.2007.03.002
G.L. Morrison, I. Budihardjo, M. Behnia, Water-in-Glass Evacuated Tube Solar Water Heaters Solar Energy. ,vol. 76, pp. 135- 140 ,(2004) , 10.1016/J.SOLENER.2003.07.024
G.L. Morrison, I. Budihardjo, M. Behnia, Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater Solar Energy. ,vol. 78, pp. 257- 267 ,(2005) , 10.1016/J.SOLENER.2004.09.005
M. Arab, M. Soltanieh, M.B. Shafii, Experimental investigation of extra-long pulsating heat pipe application in solar water heaters Experimental Thermal and Fluid Science. ,vol. 42, pp. 6- 15 ,(2012) , 10.1016/J.EXPTHERMFLUSCI.2012.03.006
I. Budihardjo, G.L. Morrison, Performance of water-in-glass evacuated tube solar water heaters Solar Energy. ,vol. 83, pp. 49- 56 ,(2009) , 10.1016/J.SOLENER.2008.06.010
Tin-Tai Chow, Zhaoting Dong, Lok-Shun Chan, Kwong-Fai Fong, Yu Bai, Performance evaluation of evacuated tube solar domestic hot water systems in Hong Kong Energy and Buildings. ,vol. 43, pp. 3467- 3474 ,(2011) , 10.1016/J.ENBUILD.2011.09.009
Oussama Ibrahim, Farouk Fardoun, Rafic Younes, Hasna Louahlia-Gualous, Review of water-heating systems: General selection approach based on energy and environmental aspects Building and Environment. ,vol. 72, pp. 259- 286 ,(2014) , 10.1016/J.BUILDENV.2013.09.006