Pulsed flows in flow analysis: Potentialities, limitations and applications.

作者: Pablo González , Moisés Knochen , Milton K Sasaki , Elias AG Zagatto , None

DOI: 10.1016/J.TALANTA.2015.05.018

关键词:

摘要: In flow analysis, use of a steady and pulseless was considered essential for ensuring reproducible handling the flowing sample. To this end, peristaltic syringe pumps have been propelling device in vast majority analysers. Recently, number applications involving pulsed has increasing. Most them refer to solenoid pumps, essence so-called multi-pumping systems. This review critically discusses characteristics, potentialities limitations systems, emphasizing main advantageous characteristics streams involved, such as high radial mass transference good mixing fluids. Diverse contributions ranging from instrumentation development analytical are presented.

参考文章(134)
Elias AG Zagatto, Claudio C Oliveira, Alan Townshend, Paul Worsfold, None, Flow analysis with spectrophotometric and luminometric detection Elsevier. ,(2012)
André F. Lavorante, Cherrine K. Pires, Boaventura F. Reis, Multicommuted flow system employing pinch solenoid valves and micro-pumps. Spectrophotometric determination of paracetamol in pharmaceutical formulations. Journal of Pharmaceutical and Biomedical Analysis. ,vol. 42, pp. 423- 429 ,(2006) , 10.1016/J.JPBA.2006.04.013
M. K. Sasaki, D. S. M. Ribeiro, C. Frigerio, J. A. V. Prior, J. L. M. Santos, E. A. G. Zagatto, Chemiluminometric determination of ascorbic acid in pharmaceutical formulations exploiting photo-activation of GSH-capped CdTe quantum dots. Luminescence. ,vol. 29, pp. 901- 907 ,(2014) , 10.1002/BIO.2639
Mrio A. Feres, Elias A. G. Zagatto, Joo L. M. Santos, Jos L. F. C. Lima, The Concept of Multi‐Commutation in Flow Analysis Wiley‐VCH Verlag GmbH & Co. KGaA. pp. 167- 202 ,(2008) , 10.1002/9783527623259.CH7
J. Ṙuz̆ic̆ka, E.H. Hansen, Flow injection analyses Analytica Chimica Acta. ,vol. 78, pp. 145- 157 ,(1975) , 10.1016/S0003-2670(01)84761-9
Fernando Albertús, Andreu Cladera, Víctor Cerdá, Burkhard Horstkotte, A robust multisyringe system for process flow analysis. Part I. On-line dilution and single point titration of protolytes Analyst. ,vol. 124, pp. 1373- 1381 ,(1999) , 10.1039/A903496J
João AV Prior, João LM Santos, José LFC Lima, None, Exploiting kinetic spectrophotometric determination of captopril, an angiotensin-converting enzyme inhibitor, in a multi-pumping flow system. Analytica Chimica Acta. ,vol. 600, pp. 183- 187 ,(2007) , 10.1016/J.ACA.2007.01.080
José LFC Lima, Sandra M Oliveira Sá, João LM Santos, Elias AG Zagatto, None, Multi-pumping flow system for the spectrophotometric determination of dipyrone in pharmaceutical preparations Journal of Pharmaceutical and Biomedical Analysis. ,vol. 32, pp. 1011- 1017 ,(2003) , 10.1016/S0731-7085(03)00203-6
Carmen Pons, Rafael Forteza, Víctor Cerdà, Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron Analytica Chimica Acta. ,vol. 550, pp. 33- 39 ,(2005) , 10.1016/J.ACA.2005.06.072
Wanessa R. Melchert, Carlos M.C. Infante, Fábio R.P. Rocha, Development and critical comparison of greener flow procedures for nitrite determination in natural waters Microchemical Journal. ,vol. 85, pp. 209- 213 ,(2007) , 10.1016/J.MICROC.2006.05.010