Synchronization of multiple spark-gap switches by a transmission line transformer

作者: Z. Liu , K. Yan , A. J. M. Pemen , G. J. J. Winands , E. J. M. Van Heesch

DOI: 10.1063/1.2132269

关键词:

摘要: … The multiple-switch unit consists of three 150 μ H air-core inductors L 3 , L 4 , and L 5 , two 1.3 nF high-voltage (dc 40 kV ) capacitors C 1 and C 2 , two air-flushed spark-gap switches S …

参考文章(5)
K. Yan, E.J.M. van Heesch, S.A. Nair, A.J.M. Pemen, A triggered spark-gap switch for high-repetition rate high-voltage pulse generation Journal of Electrostatics. ,vol. 57, pp. 29- 33 ,(2003) , 10.1016/S0304-3886(02)00093-1
K. Yan, H.W.M. Smulders, P.A.A.F. Wouters, S. Kapora, S.A. Nair, E.J.M. van Heesch, P.C.T. van der Laan, A.J.M. Pemen, A novel circuit topology for pulsed power generation Journal of Electrostatics. ,vol. 58, pp. 221- 228 ,(2003) , 10.1016/S0304-3886(03)00050-0
S T Pai, Qi Zhang, Introduction to High Power Pulse Technology WORLD SCIENTIFIC. ,(1995) , 10.1142/2311