Exploring the limits of spatial resolution in radiation dose delivery.

作者: Karl Otto , Brenda G. Clark , Calvin Huntzinger

DOI: 10.1118/1.1495865

关键词:

摘要: Flexibility and complexity in patient treatment due to advances radiotherapy techniques necessitates a simple method for evaluating spatial resolution capabilities of the dosedelivery device. Our purpose this investigation is evaluate model that describes ability radiation therapy device deliver desired dose distribution. The based on linear systems theory analogous methods used describe degradation imaging systems. A qualitative analysis using presented frequency domains. predict effects geometric conformity volumes evaluated by varying multileaf collimator leaf width magnitude spreading. Dose distributions three clinical shapes, circular shapes diameter one intensity modulated shape are evaluation. We show accurately predicts dependence these parameters. different devices can be quantified model, providing comparing machine characteristics. Also, as sites have requirements may tailor characteristics specific site.

参考文章(21)
Lijun Ma, Cedric Yu, Merhdad Sarfaraz, A dosimetric leaf-setting strategy for shaping radiation fields using a multileaf collimator Medical Physics. ,vol. 27, pp. 972- 977 ,(2000) , 10.1118/1.598961
Jiansheng Sun, Yunping Zhu, Study of dosimetric penumbra due to multileaf collimation on a medical linear accelerator International Journal of Radiation Oncology Biology Physics. ,vol. 32, pp. 1409- 1417 ,(1995) , 10.1016/0360-3016(95)00096-H
P C Williams, P Cooper, P C Williams, High-resolution field shaping utilizing a masked multileaf collimator. Physics in Medicine and Biology. ,vol. 45, pp. 2313- 2329 ,(2000) , 10.1088/0031-9155/45/8/317
R. Mohan, C. Chui, L. Lidofsky, Differential pencil beam dose computation model for photons Medical Physics. ,vol. 13, pp. 64- 73 ,(1986) , 10.1118/1.595924
David M. Shepard, Gustavo Olivera, Lisa Angelos, Otto Sauer, Paul Reckwerdt, T. Rockwell Mackie, A simple model for examining issues in radiotherapy optimization Medical Physics. ,vol. 26, pp. 1212- 1221 ,(1999) , 10.1118/1.598615
M. B. Sharpe, B. M. Miller, J. W. Wong, Compensation of x-ray beam penumbra in conformal radiotherapy. Medical Physics. ,vol. 27, pp. 1739- 1745 ,(2000) , 10.1118/1.1287283
Arthur L. Boyer, Present and future developments in radiotherapy treatment units Seminars in Radiation Oncology. ,vol. 5, pp. 146- 155 ,(1995) , 10.1016/S1053-4296(95)80007-7
Thomas Bortfeld, Uwe Oelfke, Simeon Nill, What is the optimum leaf width of a multileaf collimator? Medical Physics. ,vol. 27, pp. 2494- 2502 ,(2000) , 10.1118/1.1319524