A dosimetric leaf-setting strategy for shaping radiation fields using a multileaf collimator

作者: Lijun Ma , Cedric Yu , Merhdad Sarfaraz

DOI: 10.1118/1.598961

关键词:

摘要: A dosimetric leaf-setting strategy of using multileaf collimators (MLC) for shaping radiation fields has been developed. Existing MLC strategies are all based upon geometric criteria. This new approach, however, matches a prescribed field contour with clinically consistent The leaf positions determined an iterative optimization algorithm. An empirical dose model was developed to compare the dosimetric-based geometric-based strategies. Differences up half centimeter in and isodose lines were found between setting geometrically dosimetrically. provides ability achieve better conformation desired line. Since line that covers treatment volume is typically higher than 50% maximum dose, scalloping effects due finite width at edge or much reduced. Another benefit it separates process from planning process, this frees vendors developing detailed models various existing types future upgrades systems.

参考文章(13)
Arthur L. Boyer, Timothy G. Ochran, Carl E. Nyerick, Timothy J. Waldron, Calvin J. Huntzinger, Clinical dosimetry for implementation of a multileaf collimator Medical Physics. ,vol. 19, pp. 1255- 1261 ,(1992) , 10.1118/1.596757
Jatinder R. Palta, Daniel K. Yeung, Vincent Frouhar, Dosimetric considerations for a multileaf collimator system Medical Physics. ,vol. 23, pp. 1219- 1224 ,(1996) , 10.1118/1.597678
Y Zhu, A L Boyer, G E Desobry, Dose distributions of X-ray fields as shaped with multileaf collimators Physics in Medicine and Biology. ,vol. 37, pp. 163- 173 ,(1992) , 10.1088/0031-9155/37/1/011
M. Saiful Huq, Yan Yu, Zong-Ping Chen, N. Suntharalingam, Dosimetric characteristics of a commercial multileaf collimator. Medical Physics. ,vol. 22, pp. 241- 247 ,(1995) , 10.1118/1.597461
M. B. Sharpe, D. A. Jaffray, J. J. Battista, P. Munro, Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams Medical Physics. ,vol. 22, pp. 2065- 2074 ,(1995) , 10.1118/1.597648
Arthur Frazier, Maria Du, John Wong, Frank Vicini, Roy Taylor, Cedric Yu, Richard Matter, Alvaro Martinez, Di Yan, Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields. International Journal of Radiation Oncology Biology Physics. ,vol. 33, pp. 1229- 1238 ,(1995) , 10.1016/0360-3016(95)00203-0
G. S. Mageras, K. C. Podmaniczky, R. Mohan, A model for computer-controlled delivery of 3-D conformal treatments Medical Physics. ,vol. 19, pp. 945- 953 ,(1992) , 10.1118/1.596782
E.M. Fernandez, G.S. Shentall, W.P.M. Mayles, D.P. Dearnaley, The acceptability of a multileaf collimator as a replacement for conventional blocks. Radiotherapy and Oncology. ,vol. 36, pp. 65- 74 ,(1995) , 10.1016/0167-8140(95)01571-W
C X Yu, D Yan, M N Du, S Zhou, L J Verhey, Optimization of leaf positions when shaping a radiation field with a multileaf collimator Physics in Medicine and Biology. ,vol. 40, pp. 305- 308 ,(1995) , 10.1088/0031-9155/40/2/008