Survival of immediately loaded dental implants in deficient alveolar bone sites augmented with beta-tricalcium phosphate.

作者: Zeev Ormianer , Ady Palti , Arie Shifman

DOI: 10.1097/01.ID.0000239316.82325.8C

关键词:

摘要: Purpose:Dental implant placement in atrophic alveolar ridges often necessitates grafting procedures, followed by immediate or delayed placement. This study assessed the survival of immediately loaded dental implants placed deficient bone sites at grafting.Materials:From 1999

参考文章(15)
A Classi, S Emtiaz, D P Tarnow, Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. International Journal of Oral & Maxillofacial Implants. ,vol. 12, pp. 319- 324 ,(1997)
Schnitman Pa, Wohrle Ps, Rubenstein Je, Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. Journal of Oral Implantology. ,vol. 16, pp. 96- 105 ,(1990)
H Spiekermann, E J Richter, V K Jansen, A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. International Journal of Oral & Maxillofacial Implants. ,vol. 10, pp. 231- 243 ,(1995)
M. Chiapasco, C. Gatti, E. Rossi, W. Haeflige, T. H. Markwaldel., Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clinical Oral Implants Research. ,vol. 8, pp. 48- 57 ,(1997) , 10.1111/J.1600-0501.1997.TB00007.X
John B. Brunski, Biomechanical factors affecting the bone-dental implant interface. Clinical Materials. ,vol. 10, pp. 153- 201 ,(1992) , 10.1016/0267-6605(92)90049-Y
Ingvar Ericsson, Hans Nilson, Thomas Lindh, Krister Nilner, Kjell Randow, Immediate functional loading of Brånemark single tooth implants Clinical Oral Implants Research. ,vol. 11, pp. 26- 33 ,(2000) , 10.1034/J.1600-0501.2000.011001026.X
Charles A. Babbush, John N. Kent, Dale J. Misiek, Titanium Plasma-sprayed (TPS) Screw Implants for the reconstruction of the edentulous mandible Journal of Oral and Maxillofacial Surgery. ,vol. 44, pp. 274- 282 ,(1986) , 10.1016/0278-2391(86)90078-9
Hugh U. Cameron, Robert M. Pilliar, Ian Macnab, The effect of movement on the bonding of porous metal to bone Journal of Biomedical Materials Research. ,vol. 7, pp. 301- 311 ,(1973) , 10.1002/JBM.820070404
Thomas J. Balshi, Glenn J. Wolfinger, Immediate loading of Brånemark implants in edentulous mandibles: a preliminary report. Implant Dentistry. ,vol. 6, pp. 83- 92 ,(1997) , 10.1097/00008505-199700620-00002