High-Resolution Seismocardiogram Acquisition and Analysis System.

作者: Fábio Leitão , Eurico Moreira , Filipe Alves , Mário Lourenço , Olga Azevedo

DOI: 10.3390/S18103441

关键词:

摘要: Several devices and measurement approaches have recently been developed to perform ballistocardiogram (BCG) seismocardiogram (SCG) measurements. The development of a wireless acquisition system (hardware software), incorporating novel high-resolution micro-electro-mechanical (MEMS) accelerometer for SCG BCG signals data treatment is presented in this paper. A small accelerometer, with sensitivity up 0.164 µs/µg noise density below 6.5 µg/ Hz used applications. also incorporates electrocardiogram (ECG) acquisition, the software enables real-time visualization ECG (sensor positioned on chest). It then calculates metrics related cardiac performance as well correlation from previously performed sessions echocardiogram (ECHO) parameters. preliminarily clinical study over 22 subjects (including healthy cardiovascular patients) was test capability system. Data between exams performed. high resolution MEMS provides better signal wave recognition, enabling more consistent diagnostic technique analysis.

参考文章(18)
Eduardo Pinheiro, Octavian Postolache, Pedro Girão, None, Study on ballistocardiogram acquisition in a moving wheelchair with embedded sensors Metrology and Measurement Systems. ,vol. 19, pp. 739- 750 ,(2012) , 10.2478/V10178-012-0065-0
Da Woon Jung, Su Hwan Hwang, Hee Nam Yoon, Yu-Jin G. Lee, Do-Un Jeong, Kwang Suk Park, Nocturnal Awakening and Sleep Efficiency Estimation Using Unobtrusively Measured Ballistocardiogram IEEE Transactions on Biomedical Engineering. ,vol. 61, pp. 131- 138 ,(2014) , 10.1109/TBME.2013.2278020
Marian Walter, Benjamin Eilebrecht, Tobias Wartzek, Steffen Leonhardt, The smart car seat: personalized monitoring of vital signs in automotive applications ubiquitous computing. ,vol. 15, pp. 707- 715 ,(2011) , 10.1007/S00779-010-0350-4
Dookun Park, O. T. Inan, L. Giovangrandi, A combined heartbeat detector based on individual BCG and IPG heartbeat detectors international conference of the ieee engineering in medicine and biology society. ,vol. 2012, pp. 3428- 3431 ,(2012) , 10.1109/EMBC.2012.6346702
D. D. He, E. S. Winokur, C. G. Sodini, An ear-worn continuous ballistocardiogram (BCG) sensor for cardiovascular monitoring international conference of the ieee engineering in medicine and biology society. ,vol. 2012, pp. 5030- 5033 ,(2012) , 10.1109/EMBC.2012.6347123
Hyun Jae Baek, Gih Sung Chung, Ko Keun Kim, Kwang Suk Park, A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals international conference of the ieee engineering in medicine and biology society. ,vol. 16, pp. 150- 158 ,(2012) , 10.1109/TITB.2011.2175742
O.T. Inan, M. Etemadi, B. Widrow, G.T.A. Kovacs, Adaptive Cancellation of Floor Vibrations in Standing Ballistocardiogram Measurements Using a Seismic Sensor as a Noise Reference IEEE Transactions on Biomedical Engineering. ,vol. 57, pp. 722- 727 ,(2010) , 10.1109/TBME.2009.2018831
Eduardo Pinheiro, Octavian Postolache, Pedro Girão, None, Theory and Developments in an Unobtrusive Cardiovascular System Representation: Ballistocardiography The Open Biomedical Engineering Journal. ,vol. 4, pp. 201- 216 ,(2010) , 10.2174/1874120701004010201
Omer T. Inan, Pierre-Francois Migeotte, Kwang-Suk Park, Mozziyar Etemadi, Kouhyar Tavakolian, Ramon Casanella, John Zanetti, Jens Tank, Irina Funtova, G. Kim Prisk, Marco Di Rienzo, Ballistocardiography and Seismocardiography: A Review of Recent Advances biomedical and health informatics. ,vol. 19, pp. 1414- 1427 ,(2015) , 10.1109/JBHI.2014.2361732
Rosana Alves Dias, Filipe Serra Alves, Margaret Costa, Helder Fonseca, Jorge Cabral, Joao Gaspar, Luis Alexandre Rocha, Real-Time Operation and Characterization of a High-Performance Time-Based Accelerometer IEEE\/ASME Journal of Microelectromechanical Systems. ,vol. 24, pp. 1703- 1711 ,(2015) , 10.1109/JMEMS.2015.2487686