Conducting polymer-based biosensors

作者: A.Q. Contractor , T.N. Sureshkumar , R. Narayanan , S. Sukeerthi , Rakesh Lal

DOI: 10.1016/0013-4686(94)E0054-4

关键词:

摘要: … polymers such as polyamhne exhMs a strong dependence on the redox and protonatlon state of the polymer … enzyme m the conducting polymer matnx The enzyme catalyzed reaction of …

参考文章(12)
Gregg P. Kittlesen, Henry S. White, Mark S. Wrighton, CHEMICAL DERIVATIZATION OF MICROELECTRODE ARRAYS BY OXIDATION OF PYRROLE AND N-METHYLPYRROLE: FABRICATION OF MOLECULE-BASED ELECTRONIC DEVICES. Journal of the American Chemical Society. ,vol. 106, pp. 7389- 7396 ,(1984) , 10.1021/JA00336A016
Elizabeth W. Paul, Antonio J. Ricco, Mark S. Wrighton, Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices The Journal of Physical Chemistry. ,vol. 89, pp. 1441- 1447 ,(1985) , 10.1021/J100254A028
Philip N. Bartlett, Richard G. Whitaker, Strategies for the development of amperometric enzyme electrodes Biosensors. ,vol. 3, pp. 359- 379 ,(1987) , 10.1016/0265-928X(87)80018-4
Alan G. Macdiarmid, Jin-Chih Chiang, Wusong Huang, Brian D. Humphrey, N. L. D. Somasiri, Polyaniline: Protonic Acid Doping to the Metallic Regime Molecular Crystals and Liquid Crystals. ,vol. 125, pp. 309- 318 ,(1985) , 10.1080/00268948508080110
Mu Shaolin, Xue Huaiguo, Qian Bidong, BIOELECTROCHEMICAL RESPONSES OF THE POLYANILINE GLUCOSE OXIDASE ELECTRODE Journal of Electroanalytical Chemistry. ,vol. 304, pp. 7- 16 ,(1991) , 10.1016/0022-0728(91)85487-A
D. T. Hoa, T. N. Suresh. Kumar, N. S. Punekar, R. S. Srinivasa, R. Lal, A. Q. Contractor, A biosensor based on conducting polymers Analytical Chemistry. ,vol. 64, pp. 2645- 2646 ,(1992) , 10.1021/AC00045A031
Jolanta Ochmanska, Peter G. Pickup, In situ conductivity of poly-(3-methylthiophene) and (3-methylthiophene)x-[Ru(2,2'-bipyridine)2(3-{pyrrol-1-ylmethyl}pyridine)2]2+ Journal of Electroanalytical Chemistry and Interfacial Electrochemistry. ,vol. 297, pp. 211- 224 ,(1991) , 10.1016/0022-0728(91)85369-Z
M. L. Anson, THE ESTIMATION OF PEPSIN, TRYPSIN, PAPAIN, AND CATHEPSIN WITH HEMOGLOBIN. The Journal of General Physiology. ,vol. 22, pp. 79- 89 ,(1938) , 10.1085/JGP.22.1.79
Mirtha. Umana, Jess. Waller, Protein-modified electrodes. The glucose oxidase/polypyrrole system Analytical Chemistry. ,vol. 58, pp. 2979- 2983 ,(1986) , 10.1021/AC00127A018
Nicola C. Foulds, Christopher R. Lowe, Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases. ,vol. 82, pp. 1259- 1264 ,(1986) , 10.1039/F19868201259