Characterizing corneal shape after LASIK using a reference system intrinsic to the cornea

作者: Rosario G. Anera , Aixa Alarcón , José R. Jiménez , Luis Jiménez del Barco

DOI: 10.1364/JOSAA.27.001549

关键词:

摘要: The reliability of using a reference system intrinsic to the cornea has been evaluated in order characterize corneas subjects after refractive surgery. Data on 90 eyes operated by LASIK correct myopia and astigmatism were considered. corneal parameters (curvature radii asphericity) found with respect this are compared provided directly topographer. referenced main axes allow better characterization geometry, showing lower variability diminishing dissimilarities between different eyes. use these reduces discrepancies real experimental theoretically predicted values (21% mean relative error data versus 81% topographer data). To understand reduce differences is essential

参考文章(22)
Stephen D Klyce, David A Rice, Jianyi Wang, Analysis of the effects of astigmatism and misalignment on corneal surface reconstruction from photokeratoscopic data. Journal of Refractive Surgery. ,vol. 7, pp. 129- 140 ,(1991) , 10.3928/1081-597X-19910301-06
Esther Moreno-Barriuso, Sergio Barbero, Susana Marcos, Lourdes Llorente, Jesús Merayo Lloves, Rafael Navarro, Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Investigative Ophthalmology & Visual Science. ,vol. 42, pp. 1396- 1403 ,(2001)
Leo G. Carney, Julia C. Mainstone, Beth A. Henderson, Corneal topography and myopia. A cross-sectional study. Investigative Ophthalmology & Visual Science. ,vol. 38, pp. 311- 320 ,(1997)
Susana Marcos, Aberrations and visual performance following standard laser vision correction. Journal of Refractive Surgery. ,vol. 17, pp. 596- 601 ,(2001) , 10.3928/1081-597X-20010901-19
P.M. Kiely, G. Smith, L.G. Carney, The Mean Shape of the Human Cornea Journal of Modern Optics. ,vol. 29, pp. 1027- 1040 ,(1982) , 10.1080/713820960
T Y Baker, Ray tracing through non-spherical surfaces Proceedings of the Physical Society. ,vol. 55, pp. 361- 364 ,(1943) , 10.1088/0959-5309/55/5/302
Sandrine Hick, Jean-François Laliberté, Jean Meunier, Miguel Chagnon, Isabelle Brunette, Effects of misalignment during corneal topography Journal of Cataract and Refractive Surgery. ,vol. 33, pp. 1522- 1529 ,(2007) , 10.1016/J.JCRS.2007.05.029
J. R. Jiménez, R. G. Anera, L. Jiménez del Barco, E. Hita, Effect on laser-ablation algorithms of reflection losses and nonnormal incidence on the anterior cornea Applied Physics Letters. ,vol. 81, pp. 1521- 1523 ,(2002) , 10.1063/1.1502192
Jose R. Jiménez, Rosario G. Anera, Luis Jiménez del Barco, Enrique Hita, Predicting changes in corneal asphericity after hyperopic LASIK. Journal of Cataract and Refractive Surgery. ,vol. 29, pp. 1468- ,(2003) , 10.1016/S0886-3350(03)00599-6
Rosario G. Anera, César Villa, José R. Jiménez, Ramón Gutiérrez, Luis Jiménez del Barco, Differences between real and predicted corneal shapes after aspherical corneal ablation. Applied Optics. ,vol. 44, pp. 4528- 4532 ,(2005) , 10.1364/AO.44.004528