Light adjustable lens. New options for customized correction of presbyopia

作者: F.H. Hengerer , J. Böcker , B.H. Dick , I. Conrad-Hengerer

DOI: 10.1007/S00347-012-2557-4

关键词:

摘要: Purpose The aim of this study was a prospective evaluation new algorithms for the treatment presbyopia using light-adjustable intraocular lens (LAL). Patients and methods A total 15 patients scheduled routine cataract surgery were included in study. Following removal LAL (CalhounVision, Pasadena, CA) implanted. At approximately 2 weeks after implantation IOL adjusted to correct any residual refractive error (sphere cylinder) followed by creation customized near add (CNA) that based on individual patient pupil size one eye. fellow eye corrected emmetropia. final lock-in then performed. Results There no complications observed during or power adjustments. All demonstrated an improvement vision (0.97 ± 0.18) distance (0.78 with good intermediate (0.92 0.12) months lock-in. Conclusion This preliminary showed CNA patient's size, provided range near, following LAL.

参考文章(17)
F.H. Hengerer, A.C. Mellein, S.E. Buchner, H. Burkhard Dick, [The light-adjustable lens. Principles and clinical application]. Ophthalmologe. ,vol. 106, pp. 260- 264 ,(2009) , 10.1007/S00347-008-1909-6
Robert H Grubbs, Christian A Sandstedt, Daniel M Schwartz, Shiao H Chang, Julie A Kornfield, Light-adjustable lens: development of in vitro nomograms. Transactions of the American Ophthalmological Society. ,vol. 102, pp. 67- 74 ,(2004)
S.E. Buchner, H. Burkhard Dick, A.C. Mellein, F.H. Hengerer, Die lichtadjustierbare Linse Ophthalmologe. ,vol. 106, pp. 260- 264 ,(2009) , 10.1007/S00347-008-1909-6
T. Kohnen, D. Kook, G.U. Auffarth, V. Derhartunian, Einsatzmöglichkeiten intraokularer Multifokallinsen und Kriterien der Patientenselektion Ophthalmologe. ,vol. 105, pp. 527- 532 ,(2008) , 10.1007/S00347-008-1745-8
W. Haigis, IOL-Kalkulation bei hohen Ametropien Ophthalmologe. ,vol. 105, pp. 999- 1004 ,(2008) , 10.1007/S00347-008-1828-6
Rønnaug Brandser, Erling Haaskjold, Liv Drolsum, Accuracy of IOL calculation in cataract surgery Acta Ophthalmologica Scandinavica. ,vol. 75, pp. 162- 165 ,(2009) , 10.1111/J.1600-0420.1997.TB00115.X
Ken Hayashi, Hideyuki Hayashi, Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. Journal of Cataract and Refractive Surgery. ,vol. 31, pp. 337- 342 ,(2005) , 10.1016/J.JCRS.2004.06.042
Fritz H. Hengerer, Werner W. Hütz, Burkhard H. Dick, Ina Conrad-Hengerer, Combined correction of sphere and astigmatism using the light-adjustable intraocular lens in eyes with axial myopia Journal of Cataract and Refractive Surgery. ,vol. 37, pp. 317- 323 ,(2011) , 10.1016/J.JCRS.2010.08.037
E Wald, A Viestenz, A Langenbucher, U Schönherr, Evaluierung der refraktiven Treffsicherheithydrophober Acryllinsen Klinische Monatsblatter Fur Augenheilkunde. ,vol. 224, pp. 18- 22 ,(2007) , 10.1055/S-2006-927211
H Eleftheriadis, IOLMaster biometry: refractive results of 100 consecutive cases British Journal of Ophthalmology. ,vol. 87, pp. 960- 963 ,(2003) , 10.1136/BJO.87.8.960