Evaluation of Tubular Poly(Trimethylene Carbonate) Tissue Engineering Scaffolds in a Circulating Pulsatile Flow System

作者: Yan Song , Jos W.H. Wennink , Andre A. Poot , Istvan Vermes , Jan Feijen

DOI: 10.5301/IJAO.2011.6396

关键词:

摘要: Tubular scaffolds (internal diameter approximately 3 mm and wall thickness 0.8 mm) with a porosity of 83% an average pore size 116 μm were prepared from flexible ...

参考文章(39)
Ian Marshall, Panorea Papathanasopoulou, Karolina Wartolowska, None, Carotid flow rates and flow division at the bifurcation in healthy volunteers Physiological Measurement. ,vol. 25, pp. 691- 697 ,(2004) , 10.1088/0967-3334/25/3/009
Ivan Martin, David Wendt, Michael Heberer, The role of bioreactors in tissue engineering. Trends in Biotechnology. ,vol. 22, pp. 80- 86 ,(2004) , 10.1016/J.TIBTECH.2003.12.001
Laura Buttafoco, Paula Engbers-Buijtenhuijs, Andre A. Poot, Piet J. Dijkstra, Istvan Vermes, Jan Feijen, Physical characterization of vascular grafts cultured in a bioreactor Biomaterials. ,vol. 27, pp. 2380- 2389 ,(2006) , 10.1016/J.BIOMATERIALS.2005.10.017
Y. Song, M.M.J. Kamphuis, Z. Zhang, L.M.Th. Sterk, I. Vermes, A.A. Poot, J. Feijen, D.W. Grijpma, Flexible and elastic porous poly(trimethylene carbonate) structures for use in vascular tissue engineering Acta Biomaterialia. ,vol. 6, pp. 1269- 1277 ,(2010) , 10.1016/J.ACTBIO.2009.10.002
Menno B. Claase, Joost D. de Bruijn, Dirk W. Grijpma, Jan Feijen, Ectopic bone formation in cell-seeded poly(ethylene oxide)/poly(butylene terephthalate) copolymer scaffolds of varying porosity. Journal of Materials Science: Materials in Medicine. ,vol. 18, pp. 1299- 1307 ,(2007) , 10.1007/S10856-006-0077-Y
Kurtis I Auguste, Alfredo Quiñones-Hinojosa, Michael T Lawton, The tandem bypass: subclavian artery-to-middle cerebral artery bypass with dacron and saphenous vein grafts. Technical case report. Surgical Neurology. ,vol. 56, pp. 164- 169 ,(2001) , 10.1016/S0090-3019(01)00484-0
Hiromichi Sonoda, Shin-Ichi Urayama, Keiichi Takamizawa, Yasuhide Nakayama, Chikao Uyama, Hisataka Yasui, Takehisa Matsuda, Compliant design of artificial graft: Compliance determination by new digital X-ray imaging system-based method Journal of Biomedical Materials Research. ,vol. 60, pp. 191- 195 ,(2002) , 10.1002/JBM.10055
Song Chen, Pei‐Pei Wang, Jin‐Peng Wang, Guo‐Qiang Chen, Qiong Wu, None, Guided growth of smooth muscle cell on poly(3‐hydroxybutyrate‐co‐3‐hydroxyhexanoate) scaffolds with uniaxial microtubular structures Journal of Biomedical Materials Research Part A. ,vol. 86A, pp. 849- 856 ,(2008) , 10.1002/JBM.A.31780
J. Bale-Glickman, K. Selby, D. Saloner, O¨. Savas¸, Experimental flow studies in exact-replica phantoms of atherosclerotic carotid bifurcations under steady input conditions. Journal of Biomechanical Engineering-transactions of The Asme. ,vol. 125, pp. 38- 48 ,(2003) , 10.1115/1.1537734
Laura Buttafoco, Niels P. Boks, Paula Engbers-Buijtenhuijs, Dirk W. Grijpma, Andre A. Poot, Piet J. Dijkstra, Istvan Vermes, Jan Feijen, Porous hybrid structures based on P(DLLA-co-TMC) and collagen for tissue engineering of small-diameter blood vessels. Journal of Biomedical Materials Research Part B. ,vol. 79, pp. 425- 434 ,(2006) , 10.1002/JBM.B.30557