In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA.

作者: P HILFIKER , H QUICK , M SCHMIDT , J DEBATIN

DOI: 10.1016/S1352-8661(99)00003-4

关键词:

摘要: Percutaneous stent-grafting is increasingly employed as a less invasive alternative to surgery for the treatment of infrarenal abdominal aortic aneurysms. It requires long-term imaging follow-up, document structural integrity device, exclude perigraft channels and endograft leakages, well shrinkage aneurysmal sac. The expectation severe stent induced artifacts safety concerns have prevented 3D MRA from being used. purpose this in vitro study was investigate characteristics bifurcated graft with (3D Fourier transform fast spoiled GRE) at 1.5 T comparison those CTA. Measurement wall thickness luminal diameter were made on agar gel embedded five locations both CTA images. depicted dark ring MR Wall measurements overestimated true thickness, while diameters slightly underestimated. differences between CT not statistically significant (P = 0.67; P 0.85). Artifacts emanating platinum markers considerably MR-images. A wider area signal loss seen only insertion iliac leg into portion due overlap two radio-opaque markers. images should permit comprehensive assessment arterial lumen, perivascular tissues.

参考文章(15)
U Blum, M Langer, G Spillner, C Mialhe, F Beyersdorf, C Buitrago-Tellez, G Voshage, C Düber, V Schlosser, A H Cragg, Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. Radiology. ,vol. 198, pp. 25- 31 ,(1996) , 10.1148/RADIOLOGY.198.1.8539389
A Rozenblit, M L Marin, F J Veith, J Cynamon, S I Wahl, C W Bakal, Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT. American Journal of Roentgenology. ,vol. 165, pp. 1473- 1479 ,(1995) , 10.2214/AJR.165.6.7484590
H. P. Niendorf, J. Haustein, I. Cornelius, A. Alhassan, W. Clauß, Safety of gadolinium-DTPA: extended clinical experience. Magnetic Resonance in Medicine. ,vol. 22, pp. 222- 228 ,(1991) , 10.1002/MRM.1910220212
K. Komori, S. Kuma, D. Eguchi, J. Okazaki, K. Kawasaki, T. Onohara, S. Yamamura, H. Itoh, K. Sugimachi, Surgical strategy of abdominal aortic aneurysm with preoperative renal failure European Journal of Vascular and Endovascular Surgery. ,vol. 14, pp. 105- 108 ,(1997) , 10.1016/S1078-5884(97)80205-5
George P. Teitelbaum, Michael Raney, Mark J. Carvlin, Alan H. Matsumoto, Klemens H. Barth, Evaluation of ferromagnetism and magnetic resonance imaging artifacts of the Strecker tantalum vascular stent. CardioVascular and Interventional Radiology. ,vol. 12, pp. 125- 127 ,(1989) , 10.1007/BF02577374
K L Nelson, L M Gifford, C Lauber-Huber, C A Gross, T A Lasser, Clinical safety of gadopentetate dimeglumine. Radiology. ,vol. 196, pp. 439- 443 ,(1995) , 10.1148/RADIOLOGY.196.2.7617858