Devices and Materials in MRI

作者: Gregor Schaefers , Andreas Melzer

DOI: 10.1007/978-3-540-74658-4_26

关键词:

摘要: Magnetic resonance imaging (MRI) provides superiorvisualization of morphology, biochemistry, and physiology through differently weighted soft tissue contrasts (T 1 , T 2 fat or water suppression, etc.). In addition, its high flow sensitivity depicts functionalaspects such as blood flow, perfusion, diffusion organs. The physical nature MRI three-dimensional, spatially defined image volumes which allow guidance automatic slice orientation well device localization (tip tracking). Therefore, magnetic (MR) safety compatibility are important issues for all items, including implants, surgical tools, electronic mechatronic equipment, to be used within an MR environment. testing medical devices is required approval by regulatory agencies, e.g., the Food Drug Administration (FDA) European Union (EU) Notified Bodies.

参考文章(32)
Harald Kugel, Christoph Bremer, Marco Püschel, Roman Fischbach, Horst Lenzen, Bernd Tombach, Hugo Van Aken, Walter Heindel, Hazardous situation in the MR bore: induction in ECG leads causes fire European Radiology. ,vol. 13, pp. 690- 694 ,(2003) , 10.1007/S00330-003-1841-8
E. Mark Haacke, Robert W. Brown, Michael R. Thompson, Ramesh Venkatesan, Yu Chung N Cheng, Magnetic Resonance Imaging: Physical Principles and Sequence Design ,(1999)
K.M. Lüdeke, P. Röschmann, R. Tischler, Susceptibility artefacts in NMR imaging. Magnetic Resonance Imaging. ,vol. 3, pp. 329- 343 ,(1985) , 10.1016/0730-725X(85)90397-2
Thomas Klemm, Stephan Duda, Juergen Machann, Karen Seekamp-Rahn, Ludger Schnieder, Claus D. Claussen, Fritz Schick, MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths Journal of Magnetic Resonance Imaging. ,vol. 12, pp. 606- 615 ,(2000) , 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO;2-J
P HILFIKER, H QUICK, M SCHMIDT, J DEBATIN, In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA. Magnetic Resonance Materials in Physics Biology and Medicine. ,vol. 8, pp. 27- 32 ,(1999) , 10.1016/S1352-8661(99)00003-4
Kim Butts, John M. Pauly, Bruce L. Daniel, Stephen Kee, Alexander M. Norbash, Management of biopsy needle artifacts: techniques for RF-refocused MRI. Journal of Magnetic Resonance Imaging. ,vol. 9, pp. 586- 595 ,(1999) , 10.1002/(SICI)1522-2586(199904)9:4<586::AID-JMRI13>3.0.CO;2-X
G. Schaefers, Testing MR Safety and Compatibility IEEE Engineering in Medicine and Biology Magazine. ,vol. 27, pp. 23- 27 ,(2008) , 10.1109/EMB.2007.910267
J.P. Thiele, M.-A. Golombeck, O. Dössel, Thermal heating of human tissue induced by electromagnetic fields of magnetic resonance imaging. Biomedizinische Technik. ,vol. 47, pp. 743- 746 ,(2002) , 10.1515/BMTE.2002.47.S1B.743