EEG acquisition system based on active electrodes with common-mode interference suppression by Driving Right Leg circuit

作者: Marco Guermandi , Alessandro Bigucci , Eleonora Franchi Scarselli , Roberto Guerrieri

DOI: 10.1109/EMBC.2015.7319065

关键词:

摘要: We present a system for the acquisition of EEG signals based on active electrodes and implementing Driving Right Leg circuit (DgRL). DgRL allows single-ended amplification analog-to-digital conversion, still guaranteeing common mode rejection in excess 110 dB. This to acquire high-quality essentially removing network interference both wet dry-contact electrodes. The front-end stage is integrated electrode, minimizing system's sensitivity electrode contact quality, cable movement interference. A/D conversion can be either remote back-end or placed head as well, allowing an all-digital communication back-end. Noise band from 0.5 100 Hz comprised between 0.62 1.3 µV, depending configuration. Current consumption one channel 390 µA. Thanks its low noise, high level suppression quick setup capabilities, particularly suitable use outside clinical environments, such home care, brain-computer interfaces consumer-oriented applications.

参考文章(8)
Robert Matthews, Neil J. McDonald, Harini Anumula, Jamison Woodward, Peter J. Turner, Martin A. Steindorf, Kaichun Chang, Joseph M. Pendleton, Novel Hybrid Bioelectrodes for Ambulatory Zero-Prep EEG Measurements Using Multi-channel Wireless EEG System Foundations of Augmented Cognition. pp. 137- 146 ,(2007) , 10.1007/978-3-540-73216-7_16
Bruce B. Winter, John G. Webster, Driven-right-leg circuit design IEEE Transactions on Biomedical Engineering. ,vol. 30, pp. 62- 66 ,(1983) , 10.1109/TBME.1983.325168
Marco Guermandi, Roberto Cardu, Eleonora Franchi Scarselli, Roberto Guerrieri, Active Electrode IC for EEG and Electrical Impedance Tomography With Continuous Monitoring of Contact Impedance IEEE Transactions on Biomedical Circuits and Systems. ,vol. 9, pp. 21- 33 ,(2015) , 10.1109/TBCAS.2014.2311836
Marc R. Nuwer, Giancarlo Comi, Ronald Emerson, Anders Fuglsang-Frederiksen, Jean-Michel Guérit, Hermann Hinrichs, Akio Ikeda, Fransisco Jose C. Luccas, Peter Rappelsburger, IFCN standards for digital recording of clinical EEG Electroencephalography and Clinical Neurophysiology. ,vol. 106, pp. 259- 261 ,(1998) , 10.1016/S0013-4694(97)00106-5
Yu Mike Chi, Tzyy-Ping Jung, Gert Cauwenberghs, Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review IEEE Reviews in Biomedical Engineering. ,vol. 3, pp. 106- 119 ,(2010) , 10.1109/RBME.2010.2084078
Yu.M. Chi, G. Cauwenberghs, Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation international conference of the ieee engineering in medicine and biology society. ,vol. 2009, pp. 4218- 4221 ,(2009) , 10.1109/IEMBS.2009.5333527
Marco Guermandi, Eleonora Franchi Scarselli, Roberto Guerrieri, A Driving Right Leg Circuit (DgRL) for Improved Common Mode Rejection in Bio-Potential Acquisition Systems IEEE Transactions on Biomedical Circuits and Systems. ,vol. 10, pp. 507- 517 ,(2016) , 10.1109/TBCAS.2015.2446753
Jiawei Xu, Refet Firat Yazicioglu, Bernard Grundlehner, Pieter Harpe, Kofi A. A. Makinwa, Chris Van Hoof, A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring IEEE Transactions on Biomedical Circuits and Systems. ,vol. 5, pp. 555- 567 ,(2011) , 10.1109/TBCAS.2011.2170985