Nonlinearity parameter for tissue-mimicking materials

作者: Fang Dong , Ernest L Madsen , Michael C MacDonald , James A Zagzebski

DOI: 10.1016/S0301-5629(99)00016-2

关键词:

摘要: A finite amplitude insert-substitution method has been used to determine the ultrasonic nonlinearity parameter B/A of nine versions water-based, macroscopically uniform ultrasonically tissue-mimicking (TM) nonfat and fat materials. In this method, second harmonic following transmission through degassed distilled water with known (B/A = 5.2) unknown sample are measured. The ratio these amplitudes allows calculation sample. Measured values materials range from 5.6 6.6. These compare favorably published for soft tissues. contrast, measured two 9.8 11.1; represent low high end most fresh fatty For comparison, was commonly available materials, corn oil ethylene glycol, results in good agreement values.

参考文章(27)
Francis A. Duck, Physical properties of tissue ,(1990)
Xiu‐fen Gong, Zhe‐ming Zhu, Tao Shi, Jian‐hong Huang, Determination of the acoustic nonlinearity parameter in biological media using FAIS and ITD methods Journal of the Acoustical Society of America. ,vol. 86, pp. 1- 5 ,(1989) , 10.1121/1.398326
James A. Zagzebski Phd, Ernest L. Madsen Phd, Gary R. Frank, A teaching phantom for sonographers. Journal of Clinical Ultrasound. ,vol. 19, pp. 27- 38 ,(1991) , 10.1002/JCU.1870190107
L. E. Kinsler, A. R. Frey, H. B. Coppens, J. V. Sanders, H. Saunders, Fundamentals of Acoustics (3rd Ed.) Journal of Vibration and Acoustics-transactions of The Asme. ,vol. 105, pp. 269- 270 ,(1983) , 10.1115/1.3269099
Jason J. Rownd, Ernest L. Madsen, James A. Zagzebski, Gary R. Frank, Fang Dong, Phantoms and automated system for testing the resolution of ultrasound scanners Ultrasound in Medicine and Biology. ,vol. 23, pp. 245- 260 ,(1997) , 10.1016/S0301-5629(96)00205-0
Beth A. Schrope, Vernon L. Newhouse, Second harmonic ultrasonic blood perfusion measurement Ultrasound in Medicine & Biology. ,vol. 19, pp. 567- 579 ,(1993) , 10.1016/0301-5629(93)90080-8
Yang‐Sub Lee, Mark F. Hamilton, Time‐domain modeling of pulsed finite‐amplitude sound beams Journal of the Acoustical Society of America. ,vol. 97, pp. 906- 917 ,(1995) , 10.1121/1.412135
M M Burlew, E L Madsen, J A Zagzebski, R A Banjavic, S W Sum, A new ultrasound tissue-equivalent material. Radiology. ,vol. 134, pp. 517- 520 ,(1980) , 10.1148/RADIOLOGY.134.2.7352242
Ernest L. Madsen, Elizabeth Kelly-Fry, Gary R. Frank, Anthropomorphic phantoms for assessing systems used in ultrasound imaging of the compressed breast. Ultrasound in Medicine and Biology. ,vol. 14, pp. 183- 201 ,(1988) , 10.1016/0301-5629(88)90061-0
Ernest L. Madsen, James A. Zagzebski, Thomaz Ghilardi-Netto, An anthropomorphic torso section phantom for ultrasonic imaging. Medical Physics. ,vol. 7, pp. 43- 50 ,(1980) , 10.1118/1.594657