Glass microelectrode tip capacitance: its measurement and a method for its reduction.

作者: M. Carter Cornwall , Martin V. Thomas

DOI: 10.1016/0165-0270(81)90057-1

关键词:

摘要: The frequency response of input amplifiers used for measurement bioelectric signals from small cells is severely limited by the resistance and capacitance fine glass microelectrodes which are required these measurements. A significant improvement in can be realized employing technique neutralization. This neutralization, however, incomplete since: (1) bandwidth amplifier finite; (2) a fraction electrode isolated part cannot compensated. It therefore desirable to ensure that as low possible before method discussed measuring predicting distributed microelectrode described coating outside near tip with substance lower per unit length much 7-fold. significance improved this provides light recent advances intracellular single voltage clamp technique.

参考文章(10)
Paul Lorrain, Dale R. Corson, Electromagnetic fields and waves ,(1970)
M. V. Thomas, Microelectrode amplifier with improved method of input-capacitance neutralisation. Medical & Biological Engineering & Computing. ,vol. 15, pp. 450- 454 ,(1977) , 10.1007/BF02458001
Christian Guld, Cathode Follower and Negative Capacitance as High Input Impedance Circuits Proceedings of the IRE. ,vol. 50, pp. 1912- 1927 ,(1962) , 10.1109/JRPROC.1962.288171
W. A. Wilson, Marcia Monahan Goldner, Voltage clamping with a single microelectrode. Journal of Neurobiology. ,vol. 6, pp. 411- 422 ,(1975) , 10.1002/NEU.480060406
D. M. Unwin, R. B. Moreton, A microelectrode amplifier with f.e.t. input and facility for input capacity compensation. Medical & Biological Engineering & Computing. ,vol. 12, pp. 344- 347 ,(1974) , 10.1007/BF02477803
W. L. Nastuk, A. L. Hodgkin, The electrical activity of single muscle fibers Journal of Cellular and Comparative Physiology. ,vol. 35, pp. 39- 73 ,(1950) , 10.1002/JCP.1030350105
S.L Jacobson, G.A.R Mealing, A method for producing very low resistance micropipettes for intracellular measurements. Electroencephalography and Clinical Neurophysiology. ,vol. 48, pp. 106- 108 ,(1980) , 10.1016/0013-4694(80)90050-4
W. H. Freygang, AN ANALYSIS OF EXTRACELLULAR POTENTIALS FROM SINGLE NEURONS IN THE LATERAL GENICULATE NUCLEUS OF THE CAT The Journal of General Physiology. ,vol. 41, pp. 543- 564 ,(1958) , 10.1085/JGP.41.3.543
C R Bader, P R Macleish, E A Schwartz, A voltage-clamp study of the light response in solitary rods of the tiger salamander. The Journal of Physiology. ,vol. 296, pp. 1- 26 ,(1979) , 10.1113/JPHYSIOL.1979.SP012988
K.T. Brown, D.G. Flaming, New microelectrode techniques for intracellular work in small cells Neuroscience. ,vol. 2, pp. 813- 827 ,(1977) , 10.1016/0306-4522(77)90109-9