作者: Yu-Ling Wei
DOI: 10.1016/S0045-6535(98)00066-6
关键词:
摘要: A laboratory-scale liquid-injection incinerator was used to incinerate toluene at 750°C and PAH emission analyzed. The results indicate that the of solid-phase PAHs considerably increased when potassium hydroxide added into a fuel-lean flame; more resulted in PAHs. But this phenomenon not observed for fuel-rich flame. enhanced formation is proposed as by-product partial oxidation or incomplete burning soot secondary flame zone It suggested reducing via addition may increase