作者: M. Fallah , S. Mohammad S. Mahmoudi , M. Yari , R. Akbarpour Ghiasi
DOI: 10.1016/J.ENCONMAN.2015.11.017
关键词:
摘要: Abstract In recent years, the possibility of using low temperature heat sources has been followed as a hot topic in different research and academic centers. this regard, Kalina cycle paid lot attention because its promising features. Using engineering equation solver (EES) software, conventional exergy analysis is carried out study for driven by enhanced geothermal source. After validating developed model analysis, advanced i.e., splitting destruction rate into endogenous, exogenous, avoidable unavoidable parts, performed to provide detailed information about improvement potential system components. The results show that high efficiency improvement. It also revealed gives priority first condenser, then turbine evaporator. From however, calculated evaporator higher than turbine.