The efficacy of a self-paced VO2max test during motorized treadmill exercise.

作者: James Faulkner , Alexis R. Mauger , Brandon Woolley , Danielle Lambrick

DOI: 10.1123/IJSPP.2014-0052

关键词:

摘要: Purpose: To assess the utility of a self-paced maximal oxygen uptake (VO2max) test (SPV) in eliciting an accurate measure VO2max comparison with traditional graded exercise (GXT) during motorized treadmill exercise. Design: This was cross-sectional experimental study whereby recreationally trained men (n = 13, 25.5 ± 4.6 y) completed 2 tests (SPV, GXT) separated by 72-h recovery period. Methods: The GXT continuous and incremental, prescribed 1-km/h increases every min until attainment VO2max. SPV consisted 5 × 2-min stages incremental exercise, which were self-selected adjusted according to RPE levels (RPE 11, 15, 17, 20). Results: Although no significant differences observed between (63.9 3.3 cf 60.9 mL · kg−1 min−1, respectively, P > .05), apparent 4.7% mean difference may be practically important. 95% limits-of-agreement analysis 3.03 11.49 min−1. The...

参考文章(28)
B. D. Johnson, K. W. Saupe, J. A. Dempsey, Mechanical constraints on exercise hyperpnea in endurance athletes Journal of Applied Physiology. ,vol. 73, pp. 874- 886 ,(1992) , 10.1152/JAPPL.1992.73.3.874
PETER G. SNELL, JAMES STRAY-GUNDERSEN, BENJAMIN D. LEVINE, MEGAN N. HAWKINS, PETER B. RAVEN, Prevention of Cold Injuries during Exercise Medicine and Science in Sports and Exercise. ,vol. 38, pp. 2012- 2029 ,(2006) , 10.1249/01.MSS.0000241641.75101.64
Alexis R. Mauger, Alan J. Metcalfe, Lee Taylor, Paul C. Castle, The efficacy of the self-paced V̇O2max test to measure maximal oxygen uptake in treadmill running. Applied Physiology, Nutrition, and Metabolism. ,vol. 38, pp. 1211- 1216 ,(2013) , 10.1139/APNM-2012-0384
CARL FOSTER, ROBERT B. COYE, AMY CROWE, MAURICE DUMIT, STACEY LETTAU, HEIDI M. YOUNG, PAUL VOLKERT, Comparison of free range and graded exercise testing. Medicine and Science in Sports and Exercise. ,vol. 29, pp. 1521- 1526 ,(1996) , 10.1097/00005768-199711000-00020
SCOTT CROUTER, CARL FOSTER, PHILLIP ESTEN, GLEN BRICE, JOHN P. PORCARI, Comparison of incremental treadmill exercise and free range running. Medicine and Science in Sports and Exercise. ,vol. 33, pp. 644- 647 ,(2001) , 10.1097/00005768-200104000-00020
Peter B. Raven, James Stray-Gundersen, Megan N. Hawkins, Benjamin D. Levine, Peter G. Snell, Maximal oxygen uptake as a parametric measure of cardiorespiratory capacity Medicine and Science in Sports and Exercise. ,vol. 39, pp. 103- 107 ,(2007) , 10.1249/01.MSS.0000241641.75101.64
Roger G. Eston, Kevin L. Lamb, Gaynor Parfitt, Nicholas King, The validity of predicting maximal oxygen uptake from a perceptually-regulated graded exercise test European Journal of Applied Physiology. ,vol. 94, pp. 221- 227 ,(2005) , 10.1007/S00421-005-1327-2
J. Martin Bland, DouglasG. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet. ,vol. 327, pp. 307- 310 ,(1986) , 10.1016/S0140-6736(86)90837-8
JESPER FRANCH, KLAVS MADSEN, MOGENS S. DJURHUUS, PREBEN K. PEDERSEN, Improved running economy following intensified training correlates with reduced ventilatory demands. Medicine and Science in Sports and Exercise. ,vol. 30, pp. 1250- 1256 ,(1998) , 10.1097/00005768-199808000-00011