Electrothermal vaporization dynamic reaction cell inductively coupled plasma mass spectrometry for the determination of Fe, Co, Ni, Cu, and Zn in biological samples.

作者: Yen-Jia Tseng , Yu-Duan Tsai , Shiuh-Jen Jiang

DOI: 10.1007/S00216-007-1143-0

关键词:

摘要: Slurry sampling electrothermal vaporization dynamic reaction cell inductively coupled plasma mass spectrometry (ETV-DRC-ICP-MS) has been applied to determine Fe, Co, Ni, Cu, and Zn in biological samples. The influences of instrument operating conditions slurry preparation on the ion signals were reported. Pd was used as modifier. effectiveness ETV sample introduction technique alleviating various spectral interferences ICP-MS analysis demonstrated. This method NIST SRM 1573a tomato leaves reference material NRCC DORM-2 dogfish muscle also real samples such a tea swordfish purchased locally. Since sensitivities elements studied aqueous solution different, an analyte addition for determinations. analytical results materials agreed with certified values. precision between replicates better than 6% all detection limit estimated from curves 0.01, 0.006, 0.007, 0.004, 0.006 microg g(-1) Zn, respectively, original

参考文章(23)
Pilar Viñas, Mercedes Pardo-Martínez, Manuel Hernández-Córdoba, Slurry atomization for the determination of arsenic in baby foods using electrothermal atomic absorption spectrometry and deuterium background correction Journal of Analytical Atomic Spectrometry. ,vol. 14, pp. 1215- 1219 ,(1999) , 10.1039/A903718G
A.G Coedo, T Dorado, I Padilla, R Maibusch, H.-M Kuss, Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for steelmaking flue dust analysis Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 55, pp. 185- 196 ,(2000) , 10.1016/S0584-8547(99)00179-2
C. J. Park, Jon C. Van Loon, Peter. Arrowsmith, J. B. French, Sample analysis using plasma source mass spectrometry with electrothermal sample introduction Analytical Chemistry. ,vol. 59, pp. 2191- 2196 ,(1987) , 10.1021/AC00144A039
Scott D. Tanner, Characterization of ionization and matrix suppression in inductively coupled ‘cold’ plasma mass spectrometry Journal of Analytical Atomic Spectrometry. ,vol. 10, pp. 905- 921 ,(1995) , 10.1039/JA9951000905
D Conrad Grégoire, Douglas M Goltz, Marc M Lamoureux, Chuni L Chakrabarti, None, Vaporization of acids and their effect on analyte signal in electrothermal vaporization inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. ,vol. 9, pp. 919- 926 ,(1994) , 10.1039/JA9940900919