Slurry atomization for the determination of arsenic in baby foods using electrothermal atomic absorption spectrometry and deuterium background correction

作者: Pilar Viñas , Mercedes Pardo-Martínez , Manuel Hernández-Córdoba

DOI: 10.1039/A903718G

关键词: Nitric acidChemistryCalcinationStandard additionAnalytical chemistryCertified reference materialsSlurryDetection limitAtomic absorption spectroscopyArsenic

摘要: A procedure for accurately determining arsenic in different types of baby foods using slurried samples is developed. Compensation the background carried out a deuterium device. Suspensions prepared medium containing 0.1% m/v Triton X-100, 20% v/v concentrated hydrogen peroxide, 1% nitric acid and 0.3% nickel nitrate are directly introduced into furnace. The calcination atomization temperatures 1400 2400°C, respectively. Calibration by standard additions method. characteristic mass 23 pg detection limit 22 ng g –1 . reliability checked comparing results obtained with others based on microwave-oven sample digestion analyzing three certified reference materials. Values content ranged between 0.04 2.6 µg

参考文章(23)
Robert W Dabeka, Arthur D McKenzie, Gladys M A Lacroix, Chantal Cleroux Susan Bowe, Russell A Graham, Henry B S Conacher, Pam Verdeer, Survey of arsenic in total diet food composites and estimation of the dietary intake of arsenic by Canadian adults and children Journal of AOAC International. ,vol. 76, pp. 14- 25 ,(1993) , 10.1093/JAOAC/76.1.14
Carlos Bendicho, Margaretha T. C. de Loos-Vollebregt, Solid sampling in electrothermal atomic absorption spectrometry using commercial atomizers. A review Journal of Analytical Atomic Spectrometry. ,vol. 6, pp. 353- 374 ,(1991) , 10.1039/JA9910600353
W. Slavin, D.C. Manning, G.R. Carnrick, Fast analysis with Zeeman graphite furnace AAS Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 44, pp. 1237- 1243 ,(1989) , 10.1016/0584-8547(89)80122-3
K. Julshamn, A. Maage, E. H. Larsen, Studies of critical factors in the determination of arsenic in standard reference materials of marine origin by ETAAS:NMKL interlaboratory study Fresenius Journal of Analytical Chemistry. ,vol. 355, pp. 304- 307 ,(1996) , 10.1007/S0021663550304
M. Hoenig, P. Van Hoeyweohen, Application de la SAA électrothermique a Panalyse des matrices complexes: cas de l'arsenic dans les végétaux Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 37, pp. 817- 828 ,(1982) , 10.1016/0584-8547(82)80096-7
S�rgio N. F. Bruno, Reinaldo C. Campos, Adilson J. Curtius, Determination of lead and arsenic in wines by electrothermal atomic absorption spectrometry Journal of Analytical Atomic Spectrometry. ,vol. 9, pp. 341- 344 ,(1994) , 10.1039/JA9940900341
M. L. Cervera, R. Montoro, Critical review of the atomic spectrometric analysis of arsenic in foods Fresenius Journal of Analytical Chemistry. ,vol. 348, pp. 331- 340 ,(1994) , 10.1007/BF00323130
P Viñas, N Campillo, I López-Garcı́a, M Hernández-Córdoba, Electrothermal atomic absorption spectrometric determination of molybdenum, aluminium, chromium and manganese in milk Analytica Chimica Acta. ,vol. 356, pp. 267- 276 ,(1997) , 10.1016/S0003-2670(97)00553-9