Direct and simultaneous determination of arsenic, manganese, cobalt and nickel in urine with a multielement graphite furnace atomic absorption spectrometer.

作者: M Hsiang

DOI: 10.1016/J.TALANTA.2003.09.031

关键词: ChemistryNickelCobaltPyrolysisGraphite furnace atomic absorptionDetection limitAnalytical chemistryCalibration curveStandard curveAtomic absorption spectroscopy

摘要: Abstract A simple method was developed for the direct and simultaneous determination of arsenic (As), manganese (Mn), cobalt (Co), nickel (Ni) in urine by a multi-element graphite furnace atomic absorption spectrometer (Perkin–Elmer SIMAA 6000) equipped with transversely heated atomizer longitudinal Zeeman-effect background correction. Pd used as chemical modifier along either internal gas or containing hydrogen double stage pyrolysis process. standard reference material (SRM) Seronorm™ Trace Elements to confirm accuracy method. The optimum conditions analysis samples are at 1350 °C (using 5% H2 v/v Ar inter during first pure second stage) atomization 2100 °C. use matrix-free standards resulted concentrations all analytes within 85% (As) 110% certified values. recovery As improved when mixture 95% (v/v) applied step two-stage 1350 °C, found values were 91–110% value. recoveries real range 88–95% these four elements. detection limits 0.78 μg l−1 As, 0.054 μg l−1 Mn, 0.22 μg l−1 Co, 0.35 μg l−1 Ni. upper linear calibration curve 60 μg l−1 (As); 12 μg l−1 (Mn); (Co) 25 μg l−1 (Ni), respectively. relative deviations (R.S.D.s) SRM 2% less. R.S.D.s sample 1.6% 6.3% 7.0% 8.0%

参考文章(20)
Pilar Viñas, Mercedes Pardo-Martínez, Manuel Hernández-Córdoba, Slurry atomization for the determination of arsenic in baby foods using electrothermal atomic absorption spectrometry and deuterium background correction Journal of Analytical Atomic Spectrometry. ,vol. 14, pp. 1215- 1219 ,(1999) , 10.1039/A903718G
Gautam Samanta, Tarit Roy Chowdhury, Badal K. Mandal, Bhajan K. Biswas, Uttam K. Chowdhury, Gautam K. Basu, Chitta R. Chanda, Dilip Lodh, Dipankar Chakraborti, Flow Injection Hydride Generation Atomic Absorption Spectrometry for Determination of Arsenic in Water and Biological Samples from Arsenic-Affected Districts of West Bengal, India, and Bangladesh☆ Microchemical Journal. ,vol. 62, pp. 174- 191 ,(1999) , 10.1006/MCHJ.1999.1713
Natalia Campillo, Pilar Viñas, Ignacio López-García, Manuel Hernández-Córdoba, Determination of arsenic in biological fluids by electrothermal atomic absorption spectrometry. Analyst. ,vol. 125, pp. 313- 316 ,(2000) , 10.1039/A907596H
László Bencs, Ottó Szakács, Norbert Szoboszlai, Zsolt Ajtony, Gábor Bozsai, Characteristics of atomic absorption calibration curves with the transversely heated graphite furnace Journal of Analytical Atomic Spectrometry. ,vol. 18, pp. 105- 110 ,(2003) , 10.1039/B208198A