The void fraction in an annular channel at atmospheric pressure

作者: Roberto Evangelisti , Paolo Lupoli

DOI: 10.1016/0017-9310(69)90004-0

关键词:

摘要: Abstract The application of the γ-absorption method to meaiurement vapour volumetric fraction during forced convection boiling in a small annular channel is discussed. experimental results are presented and compared with existing theoretical models subcooled region.

参考文章(7)
L. Cimorelli, A. Premoli, MEASUREMENT OF VOID FRACTION WITH IMPEDANCE GAUGE TECHNIQUE Energia Nucl. (Milan). ,(1966)
S. Levy, Forced convection subcooled boiling—prediction of vapor volumetric fraction International Journal of Heat and Mass Transfer. ,vol. 10, pp. 951- 965 ,(1967) , 10.1016/0017-9310(67)90071-3
N. Zuber, J. A. Findlay, Average Volumetric Concentration in Two-Phase Flow Systems Journal of Heat Transfer. ,vol. 87, pp. 453- 468 ,(1965) , 10.1115/1.3689137
S. Zia Rouhani, Calculation of Steam Volume Fraction in Subcooled Boiling Journal of Heat Transfer. ,vol. 90, pp. 158- 164 ,(1968) , 10.1115/1.3597447
L. Cimorelli, R. Evangelisti, The application of the capacitance method for void fraction measurement in bulk boiling conditions International Journal of Heat and Mass Transfer. ,vol. 10, pp. 277- 288 ,(1967) , 10.1016/0017-9310(67)90145-7
P. Griffith, The Prediction of Low-Quality Boiling Voids Journal of Heat Transfer. ,vol. 86, pp. 327- 333 ,(1964) , 10.1115/1.3688684