Evaluation Of Atherosclerosis Severity Based On Carotid Artery Intima-Media Thickness Changes: A New Diagnostic Criterion.

作者: Mehravar Rafati , Mehrdad Rafati Rahimzadeh , Hassan Moladoust

DOI: 10.1016/J.ULTRASMEDBIO.2019.07.412

关键词:

摘要: Abstract This study aimed to identify instant intima-media thickness changes (ΔIMT) in the common carotid artery (CCA) during cardiac cycle order assess atherosclerosis progression. Using a computerized semi-automated method, IMT were extracted two walls of left CCA (240 consecutive patients) using B-mode ultrasound images. We found that ΔIMT increased from 8 ± 4% IMTmax controls 15 6% severe stenosis group. According multiple ordinal regression analysis, was associated with severity (odds ratio [OR], 4.95; p

参考文章(47)
Mustafa Seçil, Ahmet Yiğit Göktay, Oğuz Dicle, Aytaç Gülcü, Canan Altay, Hasan Ceçe, Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software. Diagnostic and Interventional Radiology. ,vol. 11, pp. 105- 108 ,(2005)
Ashish Das, Anup Paul, Michael D Taylor, Rupak K Banerjee, Pulsatile arterial wall-blood flow interaction with wall pre-stress computed using an inverse algorithm Biomedical Engineering Online. ,vol. 14, pp. 1- 19 ,(2015) , 10.1186/1475-925X-14-S1-S18
P.-J. Touboul, M.G. Hennerici, S. Meairs, H. Adams, P. Amarenco, N. Bornstein, L. Csiba, M. Desvarieux, S. Ebrahim, M. Fatar, R. Hernandez Hernandez, M. Jaff, S. Kownator, P. Prati, T. Rundek, M. Sitzer, U. Schminke, J.-C. Tardif, A. Taylor, E. Vicaut, K.S. Woo, F. Zannad, M. Zureik, Mannheim carotid intima-media thickness consensus (2004-2006). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006. Cerebrovascular Diseases. ,vol. 23, pp. 75- 80 ,(2007) , 10.1159/000097034
Sanghamithra Korukonda, Marvin Doyley, Visualizing the radial and circumferential strain distribution within vessel phantoms using synthetic-aperture ultrasound elastography IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control. ,vol. 59, pp. 1639- 1653 ,(2012) , 10.1109/TUFFC.2012.2370
Vaishali Naik, R. S. Gamad, P. P. Bansod, Carotid artery segmentation in ultrasound images and measurement of intima-media thickness. BioMed Research International. ,vol. 2013, pp. 801962- 801962 ,(2013) , 10.1155/2013/801962
Pierre-Jean Touboul, Patrizio Prati, Pierre-Yves Scarabin, Valérie Adrai, Emmanuel Thibout, Pierre Ducimetière, Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imaging. Journal of Hypertension. ,vol. 10, ,(1992) , 10.1097/00004872-199207001-00006
Spencer Menees, Danna Zhang, Joseph Le, Jie Chen, Geetha Raghuveer, Variations in Carotid Artery Intima–Media Thickness during the Cardiac Cycle in Children Journal of the American Society of Echocardiography. ,vol. 23, pp. 58- 63 ,(2010) , 10.1016/J.ECHO.2009.10.016
M L Bots, A Hofman, A M de Bruyn, P T de Jong, D E Grobbee, Isolated systolic hypertension and vessel wall thickness of the carotid artery. The Rotterdam Elderly Study. Arteriosclerosis, Thrombosis, and Vascular Biology. ,vol. 13, pp. 64- 69 ,(1993) , 10.1161/01.ATV.13.1.64
Guillaume Zahnd, Maciej Orkisz, André Sérusclat, Philippe Moulin, Didier Vray, Simultaneous extraction of carotid artery intima-media interfaces in ultrasound images: assessment of wall thickness temporal variation during the cardiac cycle computer assisted radiology and surgery. ,vol. 9, pp. 645- 658 ,(2014) , 10.1007/S11548-013-0945-0
Ming-Jay Chow, Jarred R. Mondonedo, Victor M. Johnson, Yanhang Zhang, Progressive structural and biomechanical changes in elastin degraded aorta. Biomechanics and Modeling in Mechanobiology. ,vol. 12, pp. 361- 372 ,(2013) , 10.1007/S10237-012-0404-9