Validation of medical volume visualization: A literature review

作者: A Pommert , K.H Höhne

DOI: 10.1016/S0531-5131(03)00310-8

关键词:

摘要: Abstract For applications of volume visualization in medicine, it is important to assure that the 3-D images show true anatomical situation, or at least know about their limitations. In this paper, various methods for evaluation image quality are reviewed. They classified based on fundamental terms diagnostic and technical quality, discussed with respect question what clues they provide how choose parameters, improve imaging procedures.

参考文章(27)
Kevin Bowyer, Validation of Medical Image Analysis Techniques Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis. pp. 567- 607 ,(2000) , 10.1117/3.831079.CH10
A. Pommert, W.-J. Höltje, N. Holzknecht, U. Tiede, K. H. Höhne, Accuracy of Images and Measurements in 3D Bone Imaging Computer Assisted Radiology / Computergestützte Radiologie. pp. 209- 215 ,(1991) , 10.1007/978-3-662-00807-2_36
Mark J. Bentum, Barthold Lichtenbelt, Mark A. Boer, Alex G. J. Nijmeijer, Marco K. Bosma, Jaap Smit, Improving image quality of volume-rendered three-dimensional medical data Medical Imaging 1996: Image Display. ,vol. 2707, pp. 32- 43 ,(1996) , 10.1117/12.238456
E G McFarland, J A Brink, J Loh, G Wang, V Argiro, D M Balfe, J P Heiken, M W Vannier, Visualization of colorectal polyps with spiral CT colography: evaluation of processing parameters with perspective volume rendering. Radiology. ,vol. 205, pp. 701- 707 ,(1997) , 10.1148/RADIOLOGY.205.3.9393524
H. Pfister, B. Lorensen, C. Bajaj, G. Kindlmann, W. Schroeder, L.S. Avila, K.M. Raghu, R. Machiraju, Jinho Lee, The transfer function bake-off IEEE Computer Graphics and Applications. ,vol. 21, pp. 16- 22 ,(2001) , 10.1109/38.920623
Michael W. Vannier, Evaluation of 3D imaging. Critical Reviews in Diagnostic Imaging. ,vol. 41, pp. 315- 378 ,(2000) , 10.3109/10408370091179235
R. Machiraju, R. Yagel, Reconstruction error characterization and control: a sampling theory approach IEEE Transactions on Visualization and Computer Graphics. ,vol. 2, pp. 364- 378 ,(1996) , 10.1109/2945.556504
Marcelo G.P Cavalcanti, John W Haller, Michael W Vannier, Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro☆ Journal of Oral and Maxillofacial Surgery. ,vol. 57, pp. 690- 694 ,(1999) , 10.1016/S0278-2391(99)90434-2
Kevin Novins, James Arvo, Controlled precision volume integration Proceedings of the 1992 workshop on Volume visualization. pp. 83- 89 ,(1992) , 10.1145/147130.147154