Evaluation of 3D reconstruction algorithms for a small animal PET camera

作者: C.A. Johnson , J. Seidel , R.E. Carson , W.R. Gandler , A. Sofer

DOI: 10.1109/23.597005

关键词:

摘要: … a 3D expectation maximization (EM) reconstruction algorithm might be well suited for this application. The authors investigated six reconstruction algorithms for the 3D SC PET camera: …

参考文章(14)
J.-S. Liow, S.C. Strother, Noise and signal decoupling in maximum likelihood reconstructions and Metz filters for PET images nuclear science symposium and medical imaging conference. pp. 901- 903 ,(1992) , 10.1109/NSSMIC.1992.301013
P M Bloomfield, S Rajeswaran, T J Spinks, S P Hume, R Myers, S Ashworth, K M Clifford, W F Jones, L G Byars, J Young, M Andreaco, C W Williams, A A Lammertsma, T Jones, The design and physical characteristics of a small animal positron emission tomograph Physics in Medicine and Biology. ,vol. 40, pp. 1105- 1126 ,(1995) , 10.1088/0031-9155/40/6/010
J. Seidel, W.R. Gandler, M.V. Green, Characteristics of a pair of small field-of-view LSO scintillation cameras IEEE Transactions on Nuclear Science. ,vol. 43, pp. 1968- 1973 ,(1996) , 10.1109/23.507255
S. Rajeswaran, D.L. Bailey, S.P. Hume, D.W. Townsend, A. Geissbuhler, J. Young, T. Jones, 2D and 3D imaging of small animals and the human radial artery with a high resolution detector for PET IEEE Transactions on Medical Imaging. ,vol. 11, pp. 386- 391 ,(1992) , 10.1109/42.158943
P E Kinahan, J S Karp, Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner Physics in Medicine and Biology. ,vol. 39, pp. 631- 642 ,(1994) , 10.1088/0031-9155/39/3/024
J.-S. Liow, S.C. Strother, Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions IEEE Transactions on Medical Imaging. ,vol. 10, pp. 563- 571 ,(1991) , 10.1109/42.108591
R.E. Carson, Yuchen Yan, B. Chodkowski, T.K. Yap, M.E. Daube-Witherspoon, Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm IEEE Transactions on Medical Imaging. ,vol. 13, pp. 526- 537 ,(1994) , 10.1109/42.310884
C.A. Johnson, Yuchen Yan, R.E. Carson, R.L. Martino, M.E. Daube-Witherspoon, A system for the 3D reconstruction of retracted-septa PET data using the EM algorithm nuclear science symposium and medical imaging conference. ,vol. 42, pp. 1223- 1227 ,(1995) , 10.1109/23.467875
H.M. Hudson, R.S. Larkin, Accelerated image reconstruction using ordered subsets of projection data IEEE Transactions on Medical Imaging. ,vol. 13, pp. 601- 609 ,(1994) , 10.1109/42.363108