Effect of Pond depth on Bacterial Die-Off

作者: H. Z. Sarikaya , A. M. Saatçi , A. F. Abdulfattah

DOI: 10.1061/(ASCE)0733-9372(1987)113:6(1350)

关键词:

摘要: The depth dependence of bacterial die-off was demonstrated experimentally both in batch models and three pilot-scale waste stabilization ponds with water depths 0.5m, 1.0m, 1.5m. dimensions the plan were 1.0 × 2.0m. fed secondary effluent a two-stage trickling filter plant. An activated sludge treatment plant used models. It concluded that pond has significant effect on coliform rate. first-order rate constant found to be inversely proportional first power depth.

参考文章(7)
Richard G. Bond, Wastewater : treatment and disposal CRC Press. ,(1974)
Earnest F. Gloyna, Waste stabilization ponds. Monograph series. World Health Organization. ,vol. 60, pp. 1- 175 ,(1971)
Andrew Eaton, A.E. Greenberg, Lenore S. Clesceri, Standard methods for the examination of water and wastewater Published in <b>1998</b> in Washington DC) by American public health association. ,(1992)
Chongrak Polprasert, Kiran K. Bhattarai, Dispersion Model for Waste Stabilization Ponds Journal of Environmental Engineering. ,vol. 111, pp. 45- 59 ,(1985) , 10.1061/(ASCE)0733-9372(1985)111:1(45)
J.F. Wehner, R.H. Wilhelm, Boundary conditions of flow reactor Chemical Engineering Science. ,vol. 50, pp. 3885- 3888 ,(1995) , 10.1016/0009-2509(96)81815-X
Octave Levenspiel, Chemical Reaction Engineering ,(1972)
H. Z. Sarikaya, A. M. Saatçi, Bacterial Die-Off in Waste Stabilization Ponds Journal of Environmental Engineering. ,vol. 113, pp. 366- 382 ,(1987) , 10.1061/(ASCE)0733-9372(1987)113:2(366)