A microbial biosensor for hydrogen sulfide monitoring based on potentiometry

作者: Ehsan Ebrahimi , Fatemeh Yazdian , Ghasem Amoabediny , Mohammad Reza Shariati , Behdokht Janfada

DOI: 10.1016/J.PROCBIO.2014.05.003

关键词:

摘要: Abstract In this study, a microbial biosensor for hydrogen sulfide (H 2 S) detection based on Thiobacillus thioparus immobilized in gelatin matrix was developed. The T. via either surface adsorption the or entrapment matrix. bacterial and concentration support were then varied order to optimize sensor response time limit both methods. optimization conducted by statistical analysis of measured with various polymer concentrations. According our experiments immobilization methods, optimized conditions method found be 1% an optical density 82. For method, 0.6% 88 selected as optimal conditions. A model developed extent methods immobilization. maximum change potential solution 23.16 mV 34.34 mV absorption method. times 160 s 105 s, respectively. is more advantageous development gas due its shorter time.

参考文章(32)
Bao You Liu, Guang Min Zhang, Xue Ling Li, Heng Chen, Effect of glutaraldehyde fixation on bacterial cells observed by atomic force microscopy Scanning. ,vol. 34, pp. 6- 11 ,(2012) , 10.1002/SCA.20269
Santoshi Sasaki, Kenji Yokoyama, Eiichi Tamiya, Isao Karube, Chisato Hayashi, Yoshiko Arikawa, Masahiko Numata, Sulfate sensor using Thiobacillus ferrooxidans Analytica Chimica Acta. ,vol. 347, pp. 275- 280 ,(1997) , 10.1016/S0003-2670(97)00170-0
Martín Ramírez, José Manuel Gómez, Germán Aroca, Domingo Cantero, Removal of hydrogen sulfide by immobilized Thiobacillus thioparus in a biotrickling filter packed with polyurethane foam Bioresource Technology. ,vol. 100, pp. 4989- 4995 ,(2009) , 10.1016/J.BIORTECH.2009.05.022
V.R. Sarath Babu, S. Patra, N.G. Karanth, M.A. Kumar, M.S. Thakur, Development of a biosensor for caffeine Analytica Chimica Acta. ,vol. 582, pp. 329- 334 ,(2007) , 10.1016/J.ACA.2006.09.017
Molly S. Shoichet, Rebecca H. Li, Melissa L. White, Shelley R. Winn, Stability of hydrogels used in cell encapsulation: An in vitro comparison of alginate and agarose Biotechnology and Bioengineering. ,vol. 50, pp. 374- 381 ,(1996) , 10.1002/(SICI)1097-0290(19960520)50:4<374::AID-BIT4>3.0.CO;2-I
Richard F Taylor, Ingrid G Marenchic, Richard H Spencer, Antibody- and receptor-based biosensors for detection and process control Analytica Chimica Acta. ,vol. 249, pp. 67- 70 ,(1991) , 10.1016/0003-2670(91)87009-V
Martin Hämmerle, Sabine Achmann, Ralf Moos, Gas Diffusion Electrodes for Use in an Amperometric Enzyme Biosensor Electroanalysis. ,vol. 20, pp. 2279- 2286 ,(2008) , 10.1002/ELAN.200804321