Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view.

作者: Alexandre R. Krempser , Roberto M. Ichinose , Antonio M. F. L. Miranda de Sá , Silvia M. Velasques de Oliveira , Michel P. Carneiro

DOI: 10.1007/S12149-013-0773-X

关键词:

摘要: Objectives The partial volume effect (PVE) has a great impact in quantitative PET/CT imaging. Correction methods have been recently proposed by many authors to make the image quantification more accurate. This work presents methodology for determining recovery coefficients (RCs) PVE correction images. It was taken into account radioactivity outside field of view (FOV), which is expected patient acquisition.

参考文章(22)
Wolfgang A Weber, Use of PET for Monitoring Cancer Therapy and for Predicting Outcome The Journal of Nuclear Medicine. ,vol. 46, pp. 983- 995 ,(2005)
R Matheoud, C Secco, P Della Monica, L Leva, G Sacchetti, E Inglese, M Brambilla, The effect of activity outside the field of view on image quality for a 3D LSO-based whole body PET/CT scanner Physics in Medicine and Biology. ,vol. 54, pp. 5861- 5872 ,(2009) , 10.1088/0031-9155/54/19/013
Nanda C. Krak, R. Boellaard, Otto S. Hoekstra, Jos W. R. Twisk, Corneline J. Hoekstra, Adriaan A. Lammertsma, Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 32, pp. 294- 301 ,(2005) , 10.1007/S00259-004-1566-1
Olivier Rousset, Arman Rahmim, Abass Alavi, Habib Zaidi, Partial Volume Correction Strategies in PET PET Clinics. ,vol. 2, pp. 235- 249 ,(2007) , 10.1016/J.CPET.2007.10.005
Giacinto Bagetta, Shinobu Sakurada, Understanding anomalous adaptation in chronic pain for successful development of disease modifying drugs. Current Opinion in Pharmacology. ,vol. 12, pp. 1- 3 ,(2012) , 10.1016/J.COPH.2011.11.002
D. W. Townsend, Dual-Modality Imaging: Combining Anatomy and Function The Journal of Nuclear Medicine. ,vol. 49, pp. 938- 955 ,(2008) , 10.2967/JNUMED.108.051276
Giampaolo Tomasi, Lula Rosso, PET imaging: implications for the future of therapy monitoring with PET/CT in oncology Current Opinion in Pharmacology. ,vol. 12, pp. 569- 575 ,(2012) , 10.1016/J.COPH.2012.07.016
Edward J. Hoffman, Sung-Cheng Huang, Michael E. Phelps, Quantitation in positron emission computed tomography: 1. Effect of object size. Journal of Computer Assisted Tomography. ,vol. 3, pp. 299- 308 ,(1979) , 10.1097/00004728-197906000-00001
Walter Jentzen, Reiner Weise, Jürgen Kupferschläger, Lutz Freudenberg, Wolfgang Brandau, Ronald Bares, Wolfgang Burchert, Andreas Bockisch, Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 35, pp. 611- 623 ,(2008) , 10.1007/S00259-007-0554-7
Shyam M. Srinivas, Thiruvenkatasamy Dhurairaj, Sandip Basu, Gonca Bural, Suleman Surti, Abass Alavi, A recovery coefficient method for partial volume correction of PET images Annals of Nuclear Medicine. ,vol. 23, pp. 341- 348 ,(2009) , 10.1007/S12149-009-0241-9