摘要: A method is presented to predict the time-dependent system unavailability, which includes consideration of detailed effects different periodic testing schemes. The FRANTIC computer code described; it has been developed study applications approach.

参考文章(4)
S.C. Chay, M. Mazumdar, Determination of Test Intervals in Certain Repairable Standby Protective Systems IEEE Transactions on Reliability. ,vol. R-24, pp. 201- 205 ,(1975) , 10.1109/TR.1975.5215152
S. Garribba, G. Reina, G. Volta, Availability of Repairable Units When Failure and Restoration Rates Age in Real Time IEEE Transactions on Reliability. ,vol. R-25, pp. 88- 94 ,(1976) , 10.1109/TR.1976.5214988
J.M. Kontoleon, Nadia Kontoleon, Availability of a System Subject to Irregular Short Supervision IEEE Transactions on Reliability. ,vol. R-24, pp. 278- 280 ,(1975) , 10.1109/TR.1975.5215191
W.E. Vesely, A time-dependent methodology for fault tree evaluation Nuclear Engineering and Design. ,vol. 13, pp. 337- 360 ,(1970) , 10.1016/0029-5493(70)90167-6