A Comparative Study of Full-Bridge Inverter Based DVR and Semi-Z-Source Inverter Based DVR

作者: VK Remya , P Parthiban , Avinash Nandakumar , None

DOI: 10.1109/ICETIETR.2018.8529017

关键词:

摘要: There is always a necessity to protect the voltage sensitive industrial systems from Power Quality (PQ) issues prevent loss of product quality and revenue. Generally, custom power devices take responsibility mitigate these PQ problems, restore thus maintain standards. Dynamic Voltage Restorer (DVR) one among which offers an economical compensation load under abnormal supply conditions. The injected in series by DVR compensates profile during events; appropriate with protects restores pre-defined values. required generated inverter circuit system. most commonly used full-bridge consists four switches. Semi-Z-Source (SZS) based same injection capability only two-switches compared inverter. in-phase technique employed both DVRs for injecting into grid. efficiency, are studied. This paper presents simulation results MATLAB/Simulink environment validate thecomparison.

参考文章(17)
Man-Chung Wong, Ying-Duo Han, Chi-Seng Lam, Stability study on dynamic voltage restorer (DVR) international conference on power electronics systems and applications. pp. 66- 71 ,(2004)
A. Kara, P. Dahler, D. Amhof, H. Gruning, Power supply quality improvement with a dynamic voltage restorer (DVR) applied power electronics conference. ,vol. 2, pp. 986- 993 ,(1998) , 10.1109/APEC.1998.654018
Dong Cao, Shuai Jiang, Xianhao Yu, Fang Zheng Peng, Low-Cost Semi-Z-source Inverter for Single-Phase Photovoltaic Systems IEEE Transactions on Power Electronics. ,vol. 26, pp. 3514- 3523 ,(2011) , 10.1109/TPEL.2011.2148728
Tofael Ahmed, Saad Mekhilef, None, Semi-Z-source inverter topology for grid-connected photovoltaic system Iet Power Electronics. ,vol. 8, pp. 63- 75 ,(2015) , 10.1049/IET-PEL.2013.0486
Changjiang Zhan, Vigna Kumaran Ramachandaramurthy, Atputharajah Arulampalam, Chris Fitzer, Stylianos Kromlidis, M Bames, Nicholas Jenkins, None, Dynamic voltage restorer based on voltage-space-vector PWM control IEEE Transactions on Industry Applications. ,vol. 37, pp. 1855- 1863 ,(2001) , 10.1109/28.968201
K. Piatek, A New Approach of DVR Control with Minimised Energy Injection international power electronics and motion control conference. pp. 1490- 1495 ,(2006) , 10.1109/EPEPEMC.2006.4778614
V.K. Ramachandaramurthy, C. Fitzer, A. Arulampalam, C. Zhan, M. Barnes, N. Jenkins, Control of a Battery Supported Dynamic Voltage Restorer IEE Proceedings - Generation, Transmission and Distribution. ,vol. 149, pp. 533- 542 ,(2002) , 10.1049/IP-GTD:20020658
Nambo Hur, Kwanghee Nam, Sangchul Won, A two-degrees-of-freedom current control scheme for deadtime compensation IEEE Transactions on Industrial Electronics. ,vol. 47, pp. 557- 564 ,(2000) , 10.1109/41.847896
N.H. Woodley, Field experience with Dynamic Voltage Restorer (DVR/sup TM/MV) systems 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077). ,vol. 4, pp. 2864- 2871 ,(2000) , 10.1109/PESW.2000.847339