Improving radiation oncology using a low-cost wireless accelerometer

作者: Farid Farahmand , K. O. Khadivi , Joel J. P. C. Rodrigues

DOI: 10.1109/LCN.2009.5355065

关键词:

摘要: Born on military applications, wireless sensor networks span over to different application fields, namely eHealth and medical applications. In this paper we discuss a high-precision, non-intrusive, wireless, accelerometer-based patient movement monitoring system (APMMS) in determining positional change patients undergoing radiation treatment. Using small accelerometer is placed patient's skin, broadcasting its precise position the receiving station connected PC control area. A threshold-based algorithm developed identify exact amount of direction. Our results indicate that, spite low-cost simplicity, APMMS highly sensitive offers accurate measurements.

参考文章(7)
S Senthilkumar, V Ramakrishnan, In-house auto cutoff sensor device for radiotherapy machine to monitor patient movements. Journal of Applied Clinical Medical Physics. ,vol. 9, pp. 82- 89 ,(2008) , 10.1120/JACMP.V9I3.2800
G J Chalmers, Structural Shielding Design for Medical Imaging X-ray Facilities (NCRP Report No 147) Physics in Medicine and Biology. ,vol. 50, pp. 4243- 4244 ,(2005) , 10.1088/0031-9155/50/17/B01
Jian-Yue Jin, Munther Ajlouni, Samuel Ryu, Qing Chen, Shidong Li, Benjamin Movsas, A technique of quantitatively monitoring both respiratory and nonrespiratory motion in patients using external body markers Medical Physics. ,vol. 34, pp. 2875- 2881 ,(2007) , 10.1118/1.2745237
N Lee, N Zhu, L Baker, E.J Shin, J.M Quivey, T.L Phillips, L Verhey, P Xia, Intra-fraction patient motion in head/neck cancer patients undergoing intensity-modulated radiation therapy (IMRT) International Journal of Radiation Oncology Biology Physics. ,vol. 57, ,(2003) , 10.1016/S0360-3016(03)01347-6
Colleen I. Dickie, Amy L. Parent, Peter W.M. Chung, Charles N. Catton, Tim Craig, Anthony M. Griffin, Tony Panzarella, Peter C. Ferguson, Jay S. Wunder, Robert S. Bell, Michael B. Sharpe, Brian O'Sullivan, Measuring interfractional and intrafractional motion with cone beam computed tomography and an optical localization system for lower extremity soft tissue sarcoma patients treated with preoperative intensity-modulated radiation therapy. International Journal of Radiation Oncology Biology Physics. ,vol. 78, pp. 1437- 1444 ,(2008) , 10.1016/J.IJROBP.2009.09.054
Manuel Bandala, Malcolm J Joyce, Tracking of internal organ motion with a six degree-of-freedom MEMS sensor: concept and simulation study Measurement Science and Technology. ,vol. 19, pp. 024006- ,(2008) , 10.1088/0957-0233/19/2/024006