Performance improvement of square microhotplate with insulation layer and heater geometry

作者: Gaurav Saxena , Roy Paily

DOI: 10.1007/S00542-014-2337-Y

关键词:

摘要: In this paper, we investigate four different heater geometries viz. Meander, S-shape, Double-Meander and Double-Spiral for their inherent thermal uniformity. Microheater with optimum dimensions of insulation layer is employed to decrease the deposition time improve Simulation studies are carried out find dimension layer, required a targeted uniformity 0.22 K/$$\upmu \mathrm{{m}}$$μm, value comparable reported literature. Meander $$8\,\upmu \mathrm{m}$$8μm nitride has resulted in an 0.174 whereas, S-shape $$4\,\upmu \mathrm{m}$$4μm 0.161 \mathrm{{m}}$$μm. With silicon carbide (SiC) only $$0.8\,\upmu \mathrm{m}$$0.8μm thick obtain 0.166 The combination two methods i.e, choice suitable geometry plus optimization dimensions, served purpose electrical while improving reducing thickness, all at nominal increment ($$7.1\,\%$$7.1%) power consumption.

参考文章(40)
Danick Briand, Thermally Isolated Microelectronic Devices for Gas Sensing Applications. Université de Neuchâtel. ,(2001)
Gwiy-Sang Chung, Jae-Min Jeong, Fabrication of micro heaters on polycrystalline 3C-SiC suspended membranes for gas sensors and their characteristics Microelectronic Engineering. ,vol. 87, pp. 2348- 2352 ,(2010) , 10.1016/J.MEE.2010.04.005
J. Laconte, C. Dupont, D. Flandre, J.-P. Raskin, SOI CMOS compatible low-power microheater optimization for the fabrication of smart gas sensors IEEE Sensors Journal. ,vol. 4, pp. 670- 680 ,(2004) , 10.1109/JSEN.2004.833516
Jae Choon Kim, Jin Taek Chung, Dong Jin Lee, Yong-Kook Kim, Jin Woo Kim, SungWoo Hwang, Byeong-Kwon Ju, Sang Kyeong Yun, Heung-Woo Park, Development of temperature feedback control system for piezo-actuated display package Sensors and Actuators A-physical. ,vol. 151, pp. 213- 219 ,(2009) , 10.1016/J.SNA.2009.02.019
Sugato Ghosh, Sayan Chatterjee, Avra Kundu, Santanu Maity, Hiranmay Saha, Thermal analysis of cantilever MEMS based Low power microheater array for the selective detection of explosive and toxic gases international symposium on physics and technology of sensors. pp. 290- 293 ,(2012) , 10.1109/ISPTS.2012.6260949
Liza Lam, Shouichi Sakakihara, Koji Ishizuka, Shoji Takeuchi, Hideyuki F. Arata, Hiroyuki Fujita, Hiroyuki Noji, Loop-mediated isothermal amplification of a single DNA molecule in polyacrylamide gel-based microchamber Biomedical Microdevices. ,vol. 10, pp. 539- 546 ,(2008) , 10.1007/S10544-008-9163-X
Jin-Ho Yoon, Bum-Joon Kim, Jung-Sik Kim, Design and fabrication of micro hydrogen gas sensors using palladium thin film Materials Chemistry and Physics. ,vol. 133, pp. 987- 991 ,(2012) , 10.1016/J.MATCHEMPHYS.2012.02.002
Danick Briand, Phuong Quyên Pham, Nicolaas F. de Rooij, Reliability of freestanding polysilicon microheaters to be used as igniters in solid propellant microthrusters Sensors and Actuators A-physical. ,vol. 135, pp. 329- 336 ,(2007) , 10.1016/J.SNA.2006.07.023
C. Tsamis, A.G. Nassiopoulou, A. Tserepi, Thermal properties of suspended porous silicon micro-hotplates for sensor applications Sensors and Actuators B: Chemical. ,vol. 95, pp. 78- 82 ,(2003) , 10.1016/S0925-4005(03)00409-X
J. Lee, C.M. Spadaccini, E.V. Mukerjee, W.P. King, Suspended Membrane Single Crystal Silicon Micro Hotplate for Differential Scanning Calorimetry international conference on micro electro mechanical systems. pp. 852- 855 ,(2009) , 10.1109/MEMSYS.2009.4805517